Limit switch, Limit switches XC Standard, XCKL, metal end plunger, 1NC+1 NO, snap action, Cable gland

Produttore:
Schneider Electric
Schneider electric

A6732b2e31b211d167cd8dbb45ad038cee38345f medium
Prezzo (IVA esclusa)
€ 62.96
Codice Nuova Elva
XCKL110
Codice produttore
XCKL110
Disponibilità
Invia RdO

This XCKL classic format limit switch has a metal end plunger and a Zamak body. This limit switch has a robust Zamak body, a modular design allowing easier maintenance and a classic format. It is IP66 and IK05 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with EN/IEC 60947.-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508, BV standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.

Specifications

CertificationsCSA
Depth30 mm
Height72-72 mm
MaterialMetal
Net Weight0.255 kg
Number of Poles2
Number of Steps1
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width52 mm

Specifications

Movement Of Operating Headlinear
Series Namestandard format
Contacts Type And Composition1 NC + 1 NO
Body Typefixed
Contact Operationsnap action
Body Materialzamak
Device Short NameXCKL
Number Of Poles2
Range Of ProductTelemecanique Limit switches XC Standard
Fixing Modeby the body
Type Of Operatorspring return plunger metal
Cable Entry1 metal cable gland entry 6-13.5 mm
Product Or Component Typelimit switch
Materialmetal
Head Typeplunger head
Type Of Approachvertical approach, 1 direction

Contractual warranty

Warranty18 months

Complementary

Height72-72 mm
[Ui] Rated Insulation Voltage300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
Electrical Durability5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 24 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 48 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Positive Opening Minimum Force45 N
Positive Openingwith
Contacts Insulation FormZb
Mechanical Durability20000000 cycles
Maximum Actuation Speed0.5 m/s
Minimum Force For Tripping15 N
Contact Code DesignationA300, AC-15 (Ue = 240 V), Ie = 3 A EN/IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A
Width52 mm
Terminals Description Iso N°1(13-14)NO || (21-22)NC
Depth30 mm
[Ithe] Conventional Enclosed Thermal Current10 A AC
Repeat Accuracy0.05 mm on the tripping points with 1 million operating cycles
Maximum Resistance Across Terminals25 MOhm IEC 60255-7 category 3
Short-Circuit Protection10 A cartridge fuse gG
Minimum Actuation Speed0.01 m/min
Electrical Connectionscrew-clamp terminals 1 x 0.34...2 x 1.5 mm²
Number Of Steps1
Net Weight0.255 kg
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60664 || 6 kV IEC 60947-1
Switch Actuationon end

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP110614EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsCSA || UL
Protective TreatmentTC
Ik Degree Of ProtectionIK05 EN 50102
Ambient Air Temperature For Operation-25-70 °C
StandardsIEC 60947-5-1 || UL 508 || EN 60947-5-1 || CSA C22.2 No 14 || IEC 60204-1 || EN 60204-1
Shock Resistance50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance25 gn 10-500 Hz)EN/IEC 60068-2-6
Ip Degree Of ProtectionIP66 conforming to EN/IEC 60529
Ambient Air Temperature For Storage-40-70 °C
Electrical Shock Protection Classclass I IEC 61140 || class I NF C 20-030

Documentazione


Spesso acquistati assieme


Altri articoli da Schneider Electric

Richiedi un preventivo