Limit switch, Limit switches XC Standard, XCKP, thermoplastic plastic roller lever var.length, 1NC+1 NO, snap, Pg11
- Produttore:
- Schneider Electric
- Prezzo (IVA esclusa)
- € 23.36
- Codice Nuova Elva
- XCKP2145G11
- Codice produttore
- XCKP2145G11
- Disponibilità
- 11 in stock
This XCKP compact format (CENELEC EN 50047) limit switch has a thermoplastic variable length roller lever and a plastic body. This limit switch has a double insulated thermoplastic body, a modular design allowing easier maintenance and a compact CENELEC EN50047 format. It is IP66 and IK04 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947.-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508 standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.
Specifications
Certifications | CCC |
---|---|
Depth | 30 mm |
Height | 65-65 mm |
Material | Plastic |
Net Weight | 0.145 kg |
Number of Poles | 2 |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Width | 31 mm |
Specifications | |
Movement Of Operating Head | rotary |
Type Of Approach | lateral approach, 2 directions |
Series Name | standard format |
Contacts Type And Composition | 1 NC + 1 NO |
Body Type | fixed |
Contact Operation | snap action |
Body Material | plastic |
Device Short Name | XCKP |
Number Of Poles | 2 |
Range Of Product | Telemecanique Limit switches XC Standard |
Fixing Mode | by the body |
Type Of Operator | spring return roller lever thermoplastic variable length |
Sensor Design | compact |
Product Or Component Type | limit switch |
Head Material | zamak |
Material | plastic |
Head Type | rotary head |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Height | 65-65 mm |
Electrical Durability | 5000000 cycles, DC-13, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C |
Positive Opening | with |
Contacts Insulation Form | Zb |
Positive Opening Minimum Torque | 0.25 N.m |
Mechanical Durability | 10000000 cycles |
Maximum Actuation Speed | 1.5 m/s |
Contact Code Designation | A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A EN/IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A |
Width | 31 mm |
Depth | 30 mm |
Minimum Torque For Tripping | 0.1 N.m |
Terminals Description Iso N°1 | (13-14)NO || (21-22)NC |
Repeat Accuracy | 0.1 mm on the tripping points with 1 million operating cycles |
Maximum Resistance Across Terminals | 25 MOhm IEC 60255-7 category 3 |
Short-Circuit Protection | 10 A cartridge fuse gG |
Electrical Connection | screw-clamp terminals 1 x 0.34...2 x 1.5 mm² |
Cable Entry | 1 entry tapped for Pg 11 cable gland |
Net Weight | 0.145 kg |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60664 || 6 kV IEC 60947-1 |
Switch Actuation | by 30° cam |
[Ui] Rated Insulation Voltage | 300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14 |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP110606EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Circularity Profile | ENVEOLI110603EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Product Certifications | UL || CSA || CCC |
Protective Treatment | TC |
Ik Degree Of Protection | IK04 EN 50102 |
Ambient Air Temperature For Operation | -25-70 °C |
Standards | IEC 60947-5-1 || CSA C22.2 No 14 || EN 60204-1 || IEC 60204-1 || UL 508 || EN 60947-5-1 |
Shock Resistance | 50 gn 11 ms IEC 60068-2-27 |
Vibration Resistance | 25 gn 10-500 Hz)IEC 60068-2-6 |
Ip Degree Of Protection | IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529 |
Ambient Air Temperature For Storage | -40-70 °C |
Electrical Shock Protection Class | class II IEC 61140 || class II NF C 20-030 |