Limit switch, Limit switches XC Standard, XCMD, thermoplastic roller lever, 1NC+1 NO, snap, 1 m

Produttore:
Schneider Electric
Schneider electric

Ca3d834bb0f10f9c73efbf8109ba50289d429770 medium
Prezzo (IVA esclusa)
€ 45.00
Codice Nuova Elva
XCMD2115L1
Codice produttore
XCMD2115L1
Disponibilità
Invia RdO

This XCMD miniature format limit switch has a thermoplastic roller lever and a Zamak body. This limit switch has a robust Zamak miniature and modular body, is pre-cabled, allowing an easier installation. It is IP66 and IK06 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947.-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508 standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.

Specifications

Cable Length1 m
CertificationsCCC
Depth16 mm
Height50-50 mm
MaterialMetal
Net Weight0.22 kg
Number of Poles2
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width30 mm

Specifications

Movement Of Operating Headrotary
Type Of Approachlateral approach, 2 directions
Series Namestandard format
Contacts Type And Composition1 NC + 1 NO
Body Typefixed
Contact Operationsnap action
Body Materialzamak
Device Short NameXCMD
Number Of Poles2
Range Of ProductTelemecanique Limit switches XC Standard
Fixing Modeby the body
Type Of Operatorspring return roller lever thermoplastic
Sensor Designminiature
Product Or Component Typelimit switch
Head Materialzamak
Materialmetal
Head Typerotary head

Contractual warranty

Warranty18 months

Complementary

Height50-50 mm
Positive Opening Minimum Force0.5 N
Positive Openingwith
Contacts Insulation FormZb
Mechanical Durability10000000 cycles
Maximum Actuation Speed1.5 m/s
Wire Insulation MaterialPvR
Minimum Force For Tripping0.1 N
Cable Composition5 x 0.75 mm²
Tracks24/31 mm
Contact Code DesignationB300, AC-15 (Ue = 240 V), Ie = 1.5 A EN/IEC 60947-5-1 appendix A || R300, DC-13 (Ue = 250 V), Ie = 0.1 A EN/IEC 60947-5-1 appendix A
Short-Circuit Protection6 A cartridge fuse gG
Width30 mm
Depth16 mm
Maximum Resistance Across Terminals25 mOhm IEC 60255-7 category 3
Electrical Connectionremovable cable connector
Cable Length1 m
Net Weight0.22 kg
[Uimp] Rated Impulse Withstand Voltage4 kV IEC 60664 || 4 kV IEC 60947-1
Switch Actuationby 30° cam
[Ui] Rated Insulation Voltage300 V 3)UL 508 || 400 V 3)IEC 60947-5-1 || 300 V 3)CSA C22.2 No 14
Electrical Durability5000000 cycles, DC-13, 120 V, 1 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 24 V, 3 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 2 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP110612EN
Sustainable Offer StatusGreen Premium product
Toxic Heavy Metal FreeYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity ProfileENVEOLI110612EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsCCC || UL || CSA
Protective TreatmentTC
Ik Degree Of ProtectionIK06 EN 62262
Ambient Air Temperature For Operation-25-70 °C
StandardsCSA C22.2 No 14 || EN/IEC 60947-5-1 || UL 508 || EN/IEC 60204-1
Shock Resistance25 gn 18 ms IEC 60068-2-27
Vibration Resistance5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of ProtectionIP66 conforming to IEC 60529 || IP67 conforming to IEC 60529 || IP68 conforming to IEC 60529
Ambient Air Temperature For Storage-40-70 °C
Overvoltage Categoryclass I IEC 61140 || class I NF C 20-030

Documentazione