Limit switch, Limit switches XC Standard, XCRT, metal enclosure zinc plated steel roller with lever, 2C/O
- Produttore:
- Schneider Electric
This industrial blue metal roller lever limit switch is part of XC special range, an offer of limit switches for conveyor belt shift monitoring applications. It features a head with zinc plated steel lever for rotary movement operators, spring return to off position. And a contact block with 2 single-pole CO snap action. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65.
Specifications
Depth | 75 mm |
---|---|
Height | 95-95 mm |
Material | Metal |
Net Weight | 1.17 kg |
Number of Poles | 2 |
Number of Steps | 2 |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Width | 85 mm |
Specifications | |
Movement Of Operating Head | rotary |
Type Of Approach | lateral approach, 2 directions |
Series Name | special format |
Contacts Type And Composition | 2 C/O |
Body Type | fixed |
Positive Opening | without |
Contact Block Per Direction [Control Circuit] | 2 per direction |
Contact Operation | snap action |
Product Specific Application | for conveyor belt shift monitoring |
Device Short Name | XCRT |
Number Of Poles | 2 |
Range Of Product | OsiSense XC |
Electrical Connection | screw-clamp terminals 1 x 0.5...2 x 2.5 mm² |
Fixing Mode | by the body |
Type Of Operator | spring return roller zinc plated steel with lever |
Product Or Component Type | limit switch |
Material | metal |
Head Type | rotary head |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Maximum Displacement Angle | -90 ° || 90 ° |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60664 || 6 kV IEC 60947-1 |
Switch Actuation | by conveyor belt |
[Ui] Rated Insulation Voltage | 300 VUL 508 || 500 V 3)IEC 60947-1 || 500 V 3)VDE 0110 || 300 VCSA C22.2 No 14 |
Electrical Durability | 5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 24 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 48 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C |
Contacts Insulation Form | Za |
Mechanical Durability | 300000 cycles |
Body Material | zinc alloy |
Contact Code Designation | A300, AC-15 (Ue = 240 V), Ie = 3 A EN/IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A |
Width | 85 mm |
Depth | 75 mm |
Height | 95-95 mm |
Minimum Torque For Tripping | 1 N.m |
Maximum Resistance Across Terminals | 25 MOhm IEC 60255-7 category 3 |
Terminals Description Iso N°1 | (11-12)NC || (13-14)NO |
Short-Circuit Protection | 10 A cartridge fuse gG |
Tripping Angle | 10 ° fault signalling || 18 ° stopping of the conveyor belt |
Minimum Actuation Speed | 0.01 m/min |
Number Of Steps | 2 |
Cable Entry | 1 entry tapped for Pg 13.5 cable gland 9-12 mm NF C 68-300 |
Net Weight | 1.17 kg |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP111136EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Ambient Air Temperature For Operation | -25-70 °C |
Standards | EN 60947-5-1 || NF C 79-130 || CSA C22.2 No 14 || IEC 60947-5-1 || IEC 60204-1 || EN 60204-1 |
Shock Resistance | 30 gn 18 ms IEC 60068-2-27 |
Vibration Resistance | 9 gn 10-500 Hz)IEC 60068-2-6 |
Ip Degree Of Protection | IP65 conforming to IEC 60529 |
Ambient Air Temperature For Storage | -40-70 °C |
Overvoltage Category | class I IEC 61140 || class I NF C 20-030 |
Protective Treatment | TC |