Safety switch, Telemecanique Safety switches XCS, metal XCSE, 1NC+2 NO, slow break, 2 entries tapped 1/2" NPT, 24 V

Produttore:
Schneider Electric
Schneider electric

2eeac6d11c5809c30e423d648c80a5389c2f0ad2 medium
Prezzo (IVA esclusa)
€ 344.61
Codice Nuova Elva
XCSE5313
Codice produttore
XCSE5313
Disponibilità
Tempo di consegna standard: 8 giorni

This XCSE Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a robust red coated rectangular Zamak body with 2 x 1/2" NPT cable gland entries, allowing for flexible installation. It has 2 normally open and 1 normally closed break-before-make (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 1 normally open and 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.

Specifications

CertificationsCSA
Depth44 mm
Height146-146 mm
MaterialMetal
Net Weight1.14 kg
Number of Poles3
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width98 mm

Specifications

[Us] Rated Supply Voltage24 V - 20...10 %
Materialmetal
Designrectangular
Head Typekey operated turret head
Contacts Type And Composition1 NC + 2 NO
Contact Operationslow-break, break before make
Local Signallingfor guard open/guard closed and locked 2 LEDs (green or orange)
Electromagnet Interlockinglocking on de-energisation and unlocking on energisation of solenoid
Number Of Poles3
Range Of ProductTelemecanique Safety switches XCS
Cable Entry2 entries tapped 1/2" NPT
Electrical Connectionterminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Locking Options Descriptionwith interlocking, locking by solenoid
Solenoid Contacts Type And Composition1 NC + 1 NO slow-break, simultaneous)
Product Or Component Typesafety switch
Signalling Circuit Voltage24/48 V 20...52 V)
Component NameXCSE

Contractual warranty

Warranty18 months

Complementary

Height146-146 mm
Net Weight1.14 kg
[Uimp] Rated Impulse Withstand Voltage6 kV EN/IEC 60947-5-1
Maximum Operating Rate10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage50 VEN/IEC 60947-1 signalling circuit
Positive Openingwith NC contact
Load Factor1
[Ie] Rated Operational Current0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
Minimum Actuator Force For Extraction20 N
Mechanical Durability1000000 cycles
Maximum Actuation Speed0.5 m/s
Short-Circuit Protection10 A cartridge fuse gG (gl)
Body Materialzamak
Safety Reliability DataB10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Width98 mm
Actuator Forcible Withdrawal Rtc2000 N
Depth44 mm
Protection Typeovervoltage protection signalling circuit
Supply Frequency50/60 Hz
Safety Levelcan reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Minimum Actuation Speed0.01 m/s
Signalling Circuit Consumption7 mA
[Ithe] Conventional Enclosed Thermal Current6 A
Power Consumption In Va10 VA inrush || 10 VA sealed
Supply Voltage TypeAC/DC
Head Materialzamak
Signalling Circuit TypeAC/DC

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP110916EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity ProfileENVEOLI110903EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsUL || CSA
Ambient Air Temperature For Operation-25-40 °C
StandardsUL 508 || CSA C22.2 No 14 || EN 1088/ISO 14119 || EN/ISO 12100 || EN/IEC 60947-5-1 || EN/IEC 60204-1
Shock Resistance10 gn 11 ms IEC 60068-2-27
Vibration Resistance5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of ProtectionIP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient Air Temperature For Storage-40-70 °C
Electrical Shock Protection Classclass I EN/IEC 61140
Protective TreatmentTC

Documentazione


Spesso acquistati assieme


Altri articoli da Schneider Electric

Richiedi un preventivo