Safety switch, Telemecanique Safety switches XCS, metal XCSE, 2NC+1 NO, slow break, 2 entries tapped Pg 13, 24 V
- Produttore:
- Schneider Electric
- Prezzo (IVA esclusa)
- € 418.50
- Codice Nuova Elva
- XCSE731121
- Codice produttore
- XCSE731121
- Disponibilità
- Tempo di consegna standard: 15 giorni
Specifications
Certifications | CSA |
---|---|
Chain/Cable Diameter | 9-12 mm |
Depth | 44 mm |
Height | 146-146 mm |
Material | Metal |
Net Weight | 1.14 kg |
Number of Poles | 3 |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Width | 98 mm |
Specifications | |
[Us] Rated Supply Voltage | 24 V - 20...10 % |
Electromagnet Interlocking | locking on de-energisation and unlocking on energisation of solenoid |
Product Or Component Type | safety switch |
Signalling Circuit Voltage | 24/48 V 20...52 V) |
Component Name | XCSE |
Cable Outer Diameter | 9-12 mm |
Material | metal |
Design | rectangular |
Number Of Poles | 3 |
Head Type | key operated turret head |
Contacts Type And Composition | 2 NC + 1 NO |
Range Of Product | Telemecanique Safety switches XCS |
Cable Entry | 2 entries tapped Pg 13.5 |
Electrical Connection | terminal 1 x 0.5...2 x 1.5 mm² with or without cable end |
Locking Options Description | with interlocking, locking by solenoid |
Contact Operation | slow-break, break before make |
Local Signalling | for guard open/guard closed and locked 2 LEDs (green or orange) |
Solenoid Contacts Type And Composition | 1 NC + 1 NO slow-break, simultaneous) |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Height | 146-146 mm |
Minimum Actuator Force For Extraction | 20 N |
Mechanical Durability | 1000000 cycles |
Maximum Actuation Speed | 0.5 m/s |
Body Material | zamak |
[Ithe] Conventional Enclosed Thermal Current | 6 A |
Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
Power Consumption In Va | 10 VA inrush || 10 VA sealed |
Supply Voltage Type | AC/DC |
Width | 98 mm |
Actuator Forcible Withdrawal Rtc | 2000 N |
Maximum Operating Rate | 10 cyc/mn for maximum durability |
Depth | 44 mm |
Head Material | zamak |
Signalling Circuit Type | AC/DC |
Protection Type | overvoltage protection signalling circuit |
Net Weight | 1.14 kg |
[Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-5-1 |
Supply Frequency | 50/60 Hz |
Safety Level | can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
[Ui] Rated Insulation Voltage | 50 VEN/IEC 60947-1 signalling circuit |
Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
Positive Opening | with NC contact |
Load Factor | 1 |
Minimum Actuation Speed | 0.01 m/s |
[Ie] Rated Operational Current | 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 |
Signalling Circuit Consumption | 7 mA |
Offer Sustainability | |
Circularity Profile | ENVEOLI110903EN |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP110916EN |
Sustainable Offer Status | Green Premium product |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Environment | |
Product Certifications | CSA || UL |
Ambient Air Temperature For Operation | -25-40 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Standards | EN/ISO 12100 || UL 508 || EN/IEC 60204-1 || EN 1088/ISO 14119 || CSA C22.2 No 14 || EN/IEC 60947-5-1 |
Electrical Shock Protection Class | class I EN/IEC 61140 |
Shock Resistance | 10 gn 11 ms IEC 60068-2-27 |
Vibration Resistance | 5 gn 10-500 Hz)IEC 60068-2-6 |
Protective Treatment | TC |
Ip Degree Of Protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |