Safety switch, Telemecanique Safety switches XCS, metal XCSE, 2NC + 1 NO, slow break, 2 entries tapped Pg 13, 24 V

Produttore:
Schneider Electric
Schneider electric

2eeac6d11c5809c30e423d648c80a5389c2f0ad2 medium
Prezzo (IVA esclusa)
€ 367.29
Codice Nuova Elva
XCSE7511
Codice produttore
XCSE7511
Disponibilità
Tempo di consegna standard: 9 giorni

This product is part of the XCS range, an offer of safety switches. The limit switch is a device that converts a mechanical motion into an electrical control signal. It has 2 normally closed + 1 normally opened, slow break contacts, normally closed contact with positive opening operation. It is a switch with a rated operational current of 1.5A at 240V AC, 3A at 120V AC, 0.27A at 250V DC, 0.55 at 125V DC and a conventional enclosed thermal current of 6A. It is designed to operate in hazardous environments. It is furnished with screw clamp terminals for electrical connection and 2 cable entry tapped for PG13 cable gland. The electromagnet interlocking on energization and unlocking on de-energization of solenoid. It offers long mechanical durability which is about 1 million operating cycles. It is an IP67 rated product. The key operated turret head limit switch has a rectangular metal body which is made of Zamak. Its dimensions are 98mm (Width) x 44mm (Depth) x 146mm (Height) and weighs 1.14kg. It is intended as far as safety is concerned all dangerous machines in all sectors are involved. Such as packaging, handling, robotics, machine tools, presses, automotive sector. This product is certified by CSA and UL. It meets CSA C22.2 No 14, EN/IEC 60947-5-1, EN/IEC 60204-1, EN/ISO 12100, EN 1088/ISO 14119 and UL 508 standards. It offers protection of operators by stopping the machine when the actuator attached to the machine guard is withdrawn from the head of the switch. Safety switches for the protection of operators, by controlling the safe opening and interlocking of guards and covers in your installations.

Specifications

CertificationsCSA
Chain/Cable Diameter9-12 mm
Depth44 mm
Height146-146 mm
MaterialMetal
Net Weight1.14 kg
Number of Poles3
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width98 mm

Specifications

[Us] Rated Supply Voltage24 V - 20...10 %
Designrectangular
Materialmetal
Head Typekey operated turret head
Contacts Type And Composition2 NC + 1 NO
Contact Operationslow-break, break before make
Local Signallingfor guard open/guard closed and locked 2 LEDs (green or orange)
Electromagnet Interlockinglocking on energisation and unlocking on de-energisation of solenoid
Cable Outer Diameter9-12 mm
Number Of Poles3
Range Of ProductTelemecanique Safety switches XCS
Cable Entry2 entries tapped Pg 13.5
Electrical Connectionterminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Locking Options Descriptionwith interlocking, locking by solenoid
Solenoid Contacts Type And Composition1 NC + 1 NO slow-break, simultaneous)
Product Or Component Typesafety switch
Signalling Circuit Voltage24/48 V 20...52 V)
Component NameXCSE

Contractual warranty

Warranty18 months

Complementary

Height146-146 mm
Net Weight1.14 kg
[Uimp] Rated Impulse Withstand Voltage6 kV EN/IEC 60947-5-1
Maximum Operating Rate10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage50 VEN/IEC 60947-1 signalling circuit
Positive Openingwith NC contact
Load Factor1
[Ie] Rated Operational Current0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
Minimum Actuator Force For Extraction20 N
Mechanical Durability1000000 cycles
Maximum Actuation Speed0.5 m/s
Short-Circuit Protection10 A cartridge fuse gG (gl)
Body Materialzamak
Safety Reliability DataB10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Width98 mm
Actuator Forcible Withdrawal Rtc2000 N
Depth44 mm
Protection Typeovervoltage protection signalling circuit
Supply Frequency50/60 Hz
Safety Levelcan reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Minimum Actuation Speed0.01 m/s
Signalling Circuit Consumption7 mA
[Ithe] Conventional Enclosed Thermal Current6 A
Power Consumption In Va10 VA inrush || 10 VA sealed
Supply Voltage TypeAC/DC
Head Materialzamak
Signalling Circuit TypeAC/DC

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP110916EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity ProfileENVEOLI110903EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsUL || CSA
Ambient Air Temperature For Operation-25-40 °C
StandardsCSA C22.2 No 14 || UL 508 || EN/ISO 12100 || EN 1088/ISO 14119 || EN/IEC 60204-1 || EN/IEC 60947-5-1
Shock Resistance10 gn 11 ms IEC 60068-2-27
Vibration Resistance5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of ProtectionIP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient Air Temperature For Storage-40-70 °C
Electrical Shock Protection Classclass I EN/IEC 61140
Protective TreatmentTC

Documentazione


Spesso acquistati assieme


Altri articoli da Schneider Electric

Richiedi un preventivo