Safety switch, Telemecanique Safety switches XCS, metal XCSE, 3 NC, slow break, 2 entries tapped Pg 13, 24 V
- Produttore:
- Schneider Electric
- Prezzo (IVA esclusa)
- € 341.96
- Codice Nuova Elva
- XCSE8311
- Codice produttore
- XCSE8311
- Disponibilità
- Invia RdO
This XCSE Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a robust red coated rectangular Zamak body with 2 x Pg 13.5 cable gland entries, allowing for flexible installation. It has 3 normally closed simultaneous (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 1 normally open and 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Specifications
Certifications | CSA |
---|---|
Chain/Cable Diameter | 9-12 mm |
Depth | 44 mm |
Height | 146-146 mm |
Material | Metal |
Net Weight | 1.14 kg |
Number of Poles | 3 |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Width | 98 mm |
Specifications | |
[Us] Rated Supply Voltage | 24 V - 20...10 % |
Design | rectangular |
Material | metal |
Head Type | key operated turret head |
Contacts Type And Composition | 3 NC |
Contact Operation | slow-break, simultaneous |
Local Signalling | for guard closed and locked 1 LED (green) |
Electromagnet Interlocking | locking on de-energisation and unlocking on energisation of solenoid |
Cable Outer Diameter | 9-12 mm |
Number Of Poles | 3 |
Range Of Product | Telemecanique Safety switches XCS |
Cable Entry | 2 entries tapped Pg 13.5 |
Electrical Connection | terminal 1 x 0.5...2 x 1.5 mm² with or without cable end |
Locking Options Description | with interlocking, locking by solenoid |
Solenoid Contacts Type And Composition | 1 NC + 1 NO slow-break, simultaneous) |
Product Or Component Type | safety switch |
Signalling Circuit Voltage | 24/48 V 20...52 V) |
Component Name | XCSE |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Height | 146-146 mm |
Net Weight | 1.14 kg |
[Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-5-1 |
Maximum Operating Rate | 10 cyc/mn for maximum durability |
[Ui] Rated Insulation Voltage | 50 VEN/IEC 60947-1 signalling circuit |
Positive Opening | with NC contact |
Load Factor | 1 |
[Ie] Rated Operational Current | 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 |
Minimum Actuator Force For Extraction | 20 N |
Mechanical Durability | 1000000 cycles |
Maximum Actuation Speed | 0.5 m/s |
Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
Body Material | zamak |
Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
Width | 98 mm |
Actuator Forcible Withdrawal Rtc | 2000 N |
Depth | 44 mm |
Protection Type | overvoltage protection signalling circuit |
Supply Frequency | 50/60 Hz |
Safety Level | can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Minimum Actuation Speed | 0.01 m/s |
Signalling Circuit Consumption | 7 mA |
[Ithe] Conventional Enclosed Thermal Current | 6 A |
Power Consumption In Va | 10 VA inrush || 10 VA sealed |
Supply Voltage Type | AC/DC |
Head Material | zamak |
Signalling Circuit Type | AC/DC |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP110916EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Circularity Profile | ENVEOLI110903EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Product Certifications | UL || CSA |
Ambient Air Temperature For Operation | -25-40 °C |
Standards | EN/IEC 60204-1 || EN/IEC 60947-5-1 || CSA C22.2 No 14 || EN/ISO 12100 || UL 508 || EN 1088/ISO 14119 |
Shock Resistance | 10 gn 11 ms IEC 60068-2-27 |
Vibration Resistance | 5 gn 10-500 Hz)IEC 60068-2-6 |
Ip Degree Of Protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |
Ambient Air Temperature For Storage | -40-70 °C |
Electrical Shock Protection Class | class I EN/IEC 61140 |
Protective Treatment | TC |