Safety switch, Telemecanique Safety switches XCS, plastic XCSPA, 1 NC + 1 NO, slow break, 1 entry tapped Pg 11

Produttore:
Schneider Electric
Schneider electric

4e67bf62410cac10204137ba8b00403ef70415cf medium
Prezzo (IVA esclusa)
€ 28.85
Codice Nuova Elva
XCSPA691
Codice produttore
XCSPA691
Disponibilità
Tempo di consegna standard: 8 giorni

Specifications

CertificationsCSA
Chain/Cable Diameter7-10 mm
Depth30 mm
Height94-94 mm
MaterialPlastic
Net Weight0.11 kg
Number of Poles2
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width30 mm

Specifications

Range Of ProductTelemecanique Safety switches XCS
Contacts Type And Composition1 NC + 1 NO
Contact Operationslow-break, make before break
Cable Outer Diameter7-10 mm
Number Of Poles2
Cable Entry1 entry tapped Pg 11
Electrical Connectionterminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Locking Options Descriptionwithout locking of actuator
Product Or Component Typesafety switch
Component NameXCSPA
Materialplastic
Designcompact
Head Typekey operated turret head

Contractual warranty

Warranty18 months

Complementary

Height94-94 mm
Positive Opening Minimum Force15 N
Insulationdouble insulated
Positive Openingwith NC contact
[Ie] Rated Operational Current6 A 120 V, AC-15, A300 EN/IEC 60947-5-1 || 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1
Mechanical Durability1000000 cycles
Maximum Actuation Speed0.5 m/s
Body MaterialPA (polyamide)
Safety Reliability DataB10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Width30 mm
Actuator Forcible Withdrawal Rtc10 N
Short-Circuit Protection10 A cartridge fuse gG (gl)
Depth30 mm
Safety Levelcan reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Minimum Actuation Speed0.01 m/s
[Ithe] Conventional Enclosed Thermal Current10 A
Head MaterialPA (polyamide)
Net Weight0.11 kg
[Uimp] Rated Impulse Withstand Voltage6 kV EN/IEC 60947-5-1
Maximum Operating Rate10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP110606EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity ProfileENVEOLI110603EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsUL || CSA
Ambient Air Temperature For Operation-25-70 °C
StandardsEN 1088/ISO 14119 || EN/IEC 60204-1 || UL 508 || EN/ISO 12100 || EN/IEC 60947-5-1 || CSA C22.2 No 14
Shock Resistance10 gn 11 ms IEC 60068-2-27
Vibration Resistance5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of ProtectionIP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient Air Temperature For Storage-40-70 °C
Electrical Shock Protection Classclass II EN/IEC 61140
Protective TreatmentTC