Guard switch, Telemecanique Safety switches XCS, XCSPL, straight lever, centred, 2NC, Pg11

Produttore:
Schneider Electric
Schneider%20electric

19d4a6a9d155feb715e836d4143ffae2f677387c medium
Prezzo (IVA esclusa)
€ 30.16
Codice Nuova Elva
XCSPL751
Codice produttore
XCSPL751
Disponibilità
Invia RdO

This XCSPL Safety Limit Switch has a stainless steel turret head rotary straight lever with an operation contact on the centered position, a double insulated plastic enclosure and a Pg 11 cable gland entry. It has 2 normally closed slow break contacts. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.

Specifications

CertificationsBG
Chain/Cable Diameter7-10 mm
Depth30 mm
Enclosure MaterialPolyamide PA66 Fibre Glass Impregnated
Height161-161 mm
MaterialPlastic
Net Weight0.095 kg
Number of Poles2
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width30 mm

Specifications

Contacts Type And Composition1 NC + 1 NC
Component NameXCSPL
Operator Direction Informationcentred
Materialplastic
Number Of Poles2
Head Typeturret head rotary lever
Range Of ProductTelemecanique Safety switches XCS
Insulationdouble insulated
Cable Entry1 entry tapped Pg 11
Clamping Connection Capacity1 x 0.5...2 x 1.5 mm² with or without cable end
Contact Operationslow-break
Type Of Operatorstraight lever
Electrical Connectionterminal
Product Or Component Typeguard switch

Contractual warranty

Warranty18 months

Complementary

Height161-161 mm
Lever Materialstainless steel
Contact Code DesignationA300, AC-15 (Ue = 120 V, Ie = 6 A)EN/IEC 60947-5-1 || A300, AC-15 (Ue = 240 V, Ie = 3 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 125 V, Ie = 0.55 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 250 V, Ie = 0.27 A)EN/IEC 60947-5-1
Tripping Angle5 °
Width30 mm
Depth30 mm
Cable Outer Diameter7-10 mm
Minimum Torque For Tripping0.1 N.m
Net Weight0.095 kg
[Uimp] Rated Impulse Withstand Voltage6 kV EN/IEC 60947-5-1
Maximum Resistance Across Terminals30 mOhm EN/IEC 60947-5-4
[Ui] Rated Insulation Voltage300 VUL 508 || 300 VCSA C22.2 No 14 || 500 V 3)EN/IEC 60947-1
Safety Levelcan reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508
Short-Circuit Protection10 A cartridge fuse gG (gl)
Positive Openingwith NC contact
Positive Opening Minimum Torque0.25 N.m
Mechanical Durability1000000 cycles
[Ithe] Conventional Enclosed Thermal Current10 A
Safety Reliability DataB10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure Materialpolyamide PA66 fibre glass impregnated

Offer Sustainability

Circularity ProfileENVEOLI110603EN
Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP110606EN
Sustainable Offer StatusGreen Premium product
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Reach RegulationFree of Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of SvhcYes

Environment

Product CertificationsUL || BG || CSA
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-70 °C
StandardsEN/IEC 60947-5-4 || EN/IEC 60204-1 || CSA C22.2 No 14 || UL 508 || EN/IEC 60947-5-1 || EN 1088/ISO 14119 || EN/ISO 12100
Electrical Shock Protection Classclass II EN/IEC 61140
Shock Resistance50 gn 11 ms IEC 60068-2-27
Vibration Resistance50 gn 10-500 Hz)IEC 60068-2-6
Protective TreatmentTH || TC
Ip Degree Of ProtectionIP67 conforming to IEC 60529

Documentazione


Spesso acquistati assieme


Altri articoli da Schneider Electric

Richiedi un preventivo