Electronic pressure sensors, Pressure sensors XM, XMLR 16 bar, G 1/4, 24 VDC, 4...20 mA, PNP, M12

Produttore:
Schneider Electric
Schneider%20electric

0d5255cfb734247fa3af6a55cd7711b104feee30 medium
Prezzo (IVA esclusa)
€ 302.84
Codice Nuova Elva
XMLR016G1P25
Codice produttore
XMLR016G1P25
Disponibilità
Tempo di consegna standard: 29 giorni

This XMLR electronic pressure sensor has a 4 digit 7-segment display. This electronic pressure transmitter sensor with digital display is designed for accurate pressure measurement and display. It is fixed directly on tubage. It provides high corrosion resistance AISI 316L stainless steel and fluorocarbon resin pressure chamber for maximum longevity. 10 million cycles mechanical durability for minimum required maintenance on your pressurized fluid circuits. It has a supply voltage of 24V DC, a solid state output (PNP) and an analog ouput of 4mA to 20mA. It provides IP65/IP67 degree of protection. It is ideal in moulding and thermoforming presses, injection machines, pneumatic systems and assembly machinery, hydraulic systems of lifting and handling equipment, pumping and fresh water treatment. It complies with EN/IEC 61326-2-3 and UL 61010-1.

Specifications

CertificationsCULus
Current50 mA
Depth42 mm
Height93 mm
Housing Material316L Stainless Steel || Polyacrylamide
Net Weight0.19 kg
StandardEN/IEC 61326-2-3
Storage Temperature-40-80 °C
Width41 mm

Specifications

Pressure Sensor Typepressure transmitter
Destruction Pressure900 psi || 62 bar || 6.2 MPa
Device Short NameXMLR
Range Of ProductTelemecanique Pressure sensors XM
Pressure Switch Type Of Operationpressure transmitter with 1 switching output
Product Or Component Typeelectronic pressure sensors
Fluid Connection TypeG 1/4 (female) DIN 3852-Y
Pressure Sensor Size232 psi || 16 bar
Controlled Fluidfresh water 0-80 °C) || air -20-80 °C) || hydraulic oil -20-80 °C) || refrigeration fluid -20-80 °C)
Maximum Permissible Accidental Pressure900 psi || 62 bar || 6.2 MPa
[Us] Rated Supply Voltage24 V DC SELV 17-33 V)

Complementary

Display Accuracy<= 1 % of the measuring range
Drift Of The Zero Point+/- 0.1 % of measuring range/°C
Time Delay Range0...50 s in steps of 1 second
Electromagnetic Compatibilitysusceptibility to electromagnetic fields 10 V/m 80...2000 MHz EN/IEC 61000-4-3 || immunity to conducted RF disturbances 10 V 0.15...80 MHz EN/IEC 61000-4-6 || surge immunity test 1 kV EN/IEC 61000-4-5 || electrical fast transient/burst immunity test 2 kV EN/IEC 61000-4-4 || electrostatic discharge immunity test 8 kV air, 4 kV contact EN/IEC 61000-4-2
Maximum Switching Current250 mA
Adjustable Range Of Switching Point On Falling Pressure11.6-225 psi || 0.08-1.55 MPa || 0.8-15.5 bar
Operating Positionany position, but disposals can falsified the measurement in case of upside down mounting
Materials In Contact With Fluidfluorocarbon FKM (Viton) || ceramic || 316L stainless steel
Net Weight0.19 kg
Minimum Differential Travel48 kPa || 7 psi || 0.48 bar
Current Consumption<= 50 mA
Electrical Connectionmale connector M12, 4 pins
Contacts Type And CompositionNO/NC programmable
Maximum Delay First Up300 ms
Analogue Output Function4...20 mA
Scale Typefixed differential
Local Signallingfor light ON when switch is actuated 1 LED (yellow)
Mechanical Durability10000000 cycles
Housing Material316L stainless steel || polyacrylamide
Measurement Accuracy<= 0.6 % of the measuring range
Protection Typeshort-circuit protection || overload protection || overvoltage protection || reverse polarity
Adjustable Range Of Switching Point On Rising Pressure18.6-232 psi || 1.28-16 bar || 0.128-1.6 MPa
Height93 mm
Drift Of The Sensitivity+/- 0.03 % of measuring range/°C
Width41 mm
Display Type4 digits 7 segments
Front Materialpolyester
[Uimp] Rated Impulse Withstand Voltage0.5 kV DC
Hysteresis<= 0.2 % of the measuring range
Depth42 mm
Response Time On Output<= 10 ms analog output || <= 5 ms discrete output
Discrete Output Typesolid state PNP, NO/NC programmable
Accuracy<= 1 % of the measuring range
Linearity Error<= 0.5 % of the measuring range
Type Of Output Signalanalogue + discrete
Display Response Time Typefast 50 ms || normal 200 ms || slow 600 ms
Maximum Voltage Drop2 V
Repeat Accuracy<= 0.2 % of the measuring range

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Reach RegulationFree of Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of SvhcYes
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsEAC || cULus
Ambient Air Temperature For Operation-20-80 °C
StandardsEN/IEC 61326-2-3 || UL 61010-1
Shock Resistance50 gn EN/IEC 60068-2-27
MarkingCE
Vibration Resistance20 gn 10-2000 Hz)EN/IEC 60068-2-6
Ip Degree Of ProtectionIP65 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529
Ambient Air Temperature For Storage-40-80 °C

Documentazione


Spesso acquistati assieme


Altri articoli da Schneider Electric

Richiedi un preventivo