Rotation monitoring for hazardous area dust, M30, Sn10mm, 6...150c/mn, NC, cable 2 m

Produttore:
Schneider Electric
Schneider electric

F2925cde17f9f09884cbca3f3997cafccf3a92d0 medium
Prezzo (IVA esclusa)
€ 206.46
Codice Nuova Elva
XSAV11373EX
Codice produttore
XSAV11373EX
Disponibilità
Invia RdO

This sensor is dedicated to rotation monitoring in hazardous areas. It complies with the 2014/34/EU - ATEX directive. It provides an economical solution for detecting slip, belt breakage, drive shaft shear and overloading. Dedicated to rotation monitoring, it is suitable for conveyor belts, bucket elevators and Archemedian screws. And also for grinders, crushers, pumps, centrifugal driers, mixers, etc. This product is a cylindrical sensor, flush mountable in metal, diameter 30mm, threaded M30 x 1.5. It features a cylindrical metal case and a 2m long cable. It has a sensing distance of 10mm. Its adjustable frequency range is 6 impluses/min to 150 impluses/min. Three-wire, DC supply, 12V to 48V, NC function, PNP solid-state output.

Specifications

Cable Length2 m
CertificationsIEC-Ex INE 17.0006
Current0-15 mA
Enclosure MaterialNickel Plated Brass
Length81 mm
MaterialMetal
StandardEN/IEC 60079-0
Thread TypeM30 X 1.5
Warranty Length18 months

Specifications

Electrical Connectioncable
Wiring Technique3-wire
Ip Degree Of ProtectionIP67 conforming to IEC 60529
Series NameApplication
Body Typefixed
[Sn] Nominal Sensing Distance10 mm
Sensor Typeinductive proximity sensor
Detector Flush Mounting Acceptanceflush mountable
Switching Capacity In Ma<= 200 mA overload and short-circuit protection
Sensor Designcylindrical M30
Enclosure MaterialNickel Plated Brass
Discrete Output TypePNP
Output Circuit TypeDC
Device Applicationrotation monitoring ATEX dust
[Us] Rated Supply Voltage12...48 V DC reverse polarity protection
Discrete Output Function1 NC
Type Of Output Signaldiscrete
Range Of ProductTelemecanique Inductive proximity sensors XS
Cable Length2 m
Sensor NameXSA
Materialmetal
Size30 mm

Contractual warranty

Warranty18 months

Complementary

Current Consumption0...15 mA no-load
Thread TypeM30 x 1.5
Sensing Range> 0.31...0.59 in (> 8...15 mm)
Adjustable Frequency Range6-150 cyc/mn
Differential Travel3...15% of Fr
Run-Up Delay At Power-Up9 s standard
Supply Voltage Limits10-58 V DC
Wire Insulation MaterialPvR
Detection Facefrontal
Cable Composition3 x 0.34 mm²
Front MaterialPPS
Status Ledoutput state 1 LED red)
Repeat Accuracy3% of Sr
Operating Zone0-8 mm
Maximum Voltage Drop<1.8 V closed state)
Threaded Length57 mm
MarkingII2 D-Ex tb IIIC T90°C Db IP67
Length81 mm
Switching Frequency<= 100 Hz

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP111006EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity ProfileENVEOLI1110045
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsINERIS 04ATEX0022 || IEC-Ex INE 17.0006
Ambient Air Temperature For Operation-20-60 °C
StandardsEN/IEC 60079-31 || EN/IEC 60079-0
Dust Zonezone 21 - 22
Directives2014/34/EU - ATEX directive
Environmental Characteristichazardous location

Documentazione