Specifications
Certifications | CE |
---|---|
Current | 42 mA |
Output Voltage | 24 V |
Storage Temperature | -30-+70 °C |
Specifications | |
Range Of Product | Telemecanique Safety light curtains XUSL |
Number Of Beams | 1 |
Product Or Component Type | single-beam prebuilt muting arms |
[Sn] Nominal Sensing Distance | 0-2.5 m |
Output Type | 2 discrete solid-state PNP (NO) |
Device Short Name | XUSZAS |
Complementary | |
Sensing Range | 0...10 cm space between package || > 32 cm space between package |
Response Time | < 100 ms |
Maximum Voltage Drop | <0.5 V |
Product Compatibility | XUSL4M |
Supply | via connector |
Output Circuit Type | DC |
Local Signalling | 2 yellow LED receiver |
[Us] Rated Supply Voltage | 24 V DC +/- 20 % |
Product Specific Application | conveyor system exit direction || conveyor system normal speed |
Current Consumption | 42 mA |
Specific Application Of Photoelectric Detector | detection of opaque parts |
Housing Colour | red RAL 3000 |
Kit Composition | transmitter + receiver || quick start guide |
Emission | IR LED |
Output Voltage | 24 V |
Detection System | through beam |
Offer Sustainability | |
Circularity Profile | ENVEOLI1406015EN |
Reach Free Of Svhc | Yes |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1406015EN |
Sustainable Offer Status | Green Premium product |
Toxic Heavy Metal Free | Yes |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Reach Regulation | Free of Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Environment | |
Product Certifications | CE |
Ambient Air Temperature For Operation | -30-+55 °C |
Directives | 98/37/EEC - machinery || 89/336/EEC - electromagnetic compatibility |
Ambient Air Temperature For Storage | -30-+70 °C |
Relative Humidity | 0-95 % without condensation |
Safety Reliability Data | PFHd = 2.73E-7 1/h |
Shock Resistance | 10 gn 16 ms IEC 61496-1 |
Vibration Resistance | 0.35 +/- 0.05 mm 10-55 Hz)IEC 61496-1 |
Ip Degree Of Protection | IP65 |