Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CE, RH side -1NC+1 NO, booted pushbutton
- Produttore:
- Schneider Electric
- Prezzo (IVA esclusa)
- € 206.69
- Codice Nuova Elva
- XY2CE1A250
- Codice produttore
- XY2CE1A250
- Disponibilità
- Invia RdO
This XY2CE Emergency Stop Rope pull Switch is designed with a right hand side anchor point, allowing operator to trigger the stop of potentially dangerous machines at any point of its working area. It operates with a maximum rope length of 70 meters. It has a Zamak body with a booted pushbutton reset, Nitrile bellows, no pilot light, and 1 normally open and 1 normally closed slow break contacts. Its B10D reliability data is 300 000. This emergency stop rope pull switch is suitable for woodworking machines, shears, conveyor systems, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works, etc. Its IP66 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-5, EN/ISO 13850, UL NISD, CSA C22.2 No 14-13 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Specifications
Certifications | CCC |
---|---|
Net Weight | 1.45 kg |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Specifications | |
Range Of Product | Telemecanique Emergency stop rope pull switches XY2C |
Product Or Component Type | latching emergency stop rope pull switch |
Housing Colour | red RAL 3000 |
Overvoltage Category | class I EN/IEC 61140 || class I NF C 20-030 |
Device Short Name | XY2CE |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Reset | by booted push-button |
[Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-1 |
Trigger Cable Maximum Length | 70 m |
Connections - Terminals | screw clamp terminal, 1 x 0.5...2 x 1.5 mm² |
Contacts Type And Composition | 1 NC + 1 NO |
[Ui] Rated Insulation Voltage | 500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14 |
[Ie] Rated Operational Current | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A |
Contact Operation | slow-break |
Distance Between Cable Supports | 5-5 m |
Mechanical Durability | 60000 cycles |
Cable Entry Number | 3 plain hole Pg 13.5 or ISO M20 cable gland |
Number Of Cables | 1 |
Compatibility Code | XY2CE |
Body Material | zamak |
Trigger Cable Anchor Point | RH side |
Safety Reliability Data | B10d = 300000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5 |
Cover Material | stainless steel |
Tightening Torque | 0.8-1.2 N.m |
Maximum Resistance Across Terminals | 25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A |
Safety Level | can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Terminals Description Iso N°1 | (13-14)NO || (21-22)NC |
Short-Circuit Protection | 10 A cartridge fuse gG EN/IEC 60269 |
Positive Opening | with EN/IEC 60947-5-1 |
[Ithe] Conventional Enclosed Thermal Current | 10 A |
Marking | CE |
Local Signalling | without pilot light |
Net Weight | 1.45 kg |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP111159EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Ambient Air Temperature For Operation | -25-70 °C |
Standards | CSA C22.2 No 14 || EN/IEC 60947-5-1 || EN/IEC 60947-5-5 || UL 508 || EN/ISO 13850 || work equipment directive 2009/104/EC || EN/IEC 60204-1 || machinery directive 2006/42/EC |
Product Certifications | UL category NISD emergency stop devices || CSA || CCC |
Shock Resistance | 50 gn 11 ms EN/IEC 60068-2-27 |
Vibration Resistance | 10 gn 10-300 Hz)EN/IEC 60068-2-6 |
Ip Degree Of Protection | IP66 IEC 60529 |
Ambient Air Temperature For Storage | -40-70 °C |
Protective Treatment | TC |