Limit switch body, Limit switches XC Standard, ZCKJ, fixed, w/o display, 1NC+2 NO, snap action, M20

Produttore:
Schneider Electric
Schneider electric

B342408d08a23f0c7f8160e118da5be0f1786d17 medium
Prezzo (IVA esclusa)
€ 49.82
Codice Nuova Elva
ZCKJD31H29
Codice produttore
ZCKJD31H29
Disponibilità
Invia RdO

This product is part of the XC Standard range, an offer of limit switches. This limit switch body has 1 NC and 2 NO, snap action contacts. It is a limit switch body with a conventional enclosed thermal current of 6A and rated operating current of 1.5A at 240V AC and 0.1A at 250V DC. It is furnished with screw terminals for electrical connection. It is an IP66 and IK07 rated product. This fixed limit switch body is made of metal. Its dimensions are 40mm (width) x 44mm (depth) x 77mm (height). It weighs 0.31kg. It is intended for all industrial machine applications such as packaging, materials handling, conveying, machining, food and beverage, service sector, etc. It is compatible with the XCKJ limit switches. The associated heads are ZCKE629, ZCKE67, ZCKE62, ZCKE64, ZCKE23, ZCKE61, ZCKE05, ZCKE63, ZCKE08, ZCKE65 and ZCKE619. Limit switches for contact sensing of inflexible objects. An offer of positive opening snap action contacts for a simpler and safer machine design. IEC standard format limit switches consist of products designed according to EN 50047, EN 50041 as well as popular XCM and XCKM limit switches ranges.

Specifications

Contact MaterialSilver Plated Contacts
Depth44 mm
Height77-77 mm
Net Weight0.31 kg
Number of Poles3
Number of Steps1 1
Storage Temperature-40-70 °C
Warranty Length18 months
Width40 mm

Specifications

Series Namestandard format
Product Or Component Typelimit switch body
Product CompatibilityXCKJ
Number Of Steps1 1 position
Device Short NameZCKJ
Number Of Poles3
Contacts Type And Composition1 NC + 2 NO
Body Typefixed
Range Of ProductTelemecanique Limit switches XC Standard
Contact Operationsnap action
Contacts Materialsilver plated contacts
Associated HeadZCKE629 || ZCKE67 || ZCKE62 || ZCKE64 || ZCKE23 || ZCKE61 || ZCKE05 || ZCKE63 || ZCKE08 || ZCKE65 || ZCKE06 || ZCKE66 || ZCKE619 || ZCKE21
Body Materialmetal
Cable Entry1 entry tapped for M20 x 1.5 cable gland

Contractual warranty

Warranty18 months

Complementary

Height77-77 mm
[Ithe] Conventional Enclosed Thermal Current6 A
Width40 mm
Depth44 mm
Local Displaywithout
Net Weight0.31 kg
[Uimp] Rated Impulse Withstand Voltage4 kV IEC 60664 || 4 kV IEC 60947-1
Maximum Resistance Across Terminals0.25 mOhm IEC 60255-7 category 3
Electrical Durability5000000 cycles, DC-13 120 V, 2 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13 24 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13 48 V, 3 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Terminals Description Iso N°1(31-32)NC || (13-14)NO || (21-22)NC
Short-Circuit Protection6 A cartridge fuse gG
[Ui] Rated Insulation Voltage400 V 3)IEC 60947-1 contact block || 300 VCSA C22.2 No 14 contact block || 300 VUL 508 contact block
Positive Openingwith
Minimum Actuation Speed0.01 m/min
[Ie] Rated Operational Current1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 appendix A || 0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1 appendix A
Electrical Connectionscrew-clamp terminals 1 x 0.34...2 x 0.75 mm²

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP110614EN
Sustainable Offer StatusGreen Premium product
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Ambient Air Temperature For Storage-40-70 °C
Environmental Characteristicstandard environment
Ambient Air Temperature For Operation-25-70 °C standard environment
Ik Degree Of ProtectionIK07
Ip Degree Of ProtectionIP66

Documentazione


Altri articoli da Schneider Electric

Richiedi un preventivo