UR20-4AI-UI-16

Produttore:
WEIDMULLER
Weidmüller

C1b48eaab513af19134fa7a7218017ae7f70cba1 medium
Prezzo (IVA esclusa)
€ 321.85
Codice Nuova Elva
1315620000
Codice produttore
1315620000
Disponibilità
1 in stock

Remote I/O module, IP20, 4-channel, Analog signals, Input, Current/Voltage, 16 Bit

Specifications

Depth2.992 in
Height120 mm
Max. Operating Temperature60 °C
Min. Operating Temperature-20 °C
Module TypeAnalogue Input Module
Net Weight89 g
Operating Temperature-20 °C ... +60 °C
Storage Temperature-40 °C ... +85 °C
Width0.453 in

Dimensions And Weights

Width11.5 mm
Width (inches)0.453 inch
Height120 mm
Height (inches)4.724 inch
Depth76 mm
Depth (inches)2.992 inch
Mounting dimension - height128 mm
Net weight89 g

Temperatures

Operating temperature, max.60 °C
Operating temperature, min.-20 °C
Storage temperature, max.85 °C
Storage temperature, min.-40 °C
Operating temperature-20 °C ... +60 °C
Storage temperature-40 °C ... +85 °C

Environmental Product Compliance

REACH SVHCLead 7439-92-1

Analogue Inputs

Accuracy0.1% FSR
Sensor connection2-wire, 3-wire, 3-wire + FE
Short-circuit-proofYes
Type1. U (0…5 V, 0…10 V, 1…5 V, 2…10 V, ±10 V), 2. I (0–20 mA or 4–20 mA), Adjustable input for current or voltage
Conversion time1 ms
Individual channel diagnosisNo
Internal resistance I41.2 Ω
Internal resistance U100 kΩ
Module diagnosisYes
Number of analogue inputs4
Resolution16 Bit
Reverse polarity protectionYes

Connection Data

Type of connectionPUSH IN
Wire connection cross section, finely stranded, max.1.5 mm²
Wire connection cross-section, finely stranded, min.0.14 mm²
Wire cross-section, finely stranded, max. (AWG)AWG 16
Wire cross-section, finely stranded, min. (AWG)AWG 26
Wire cross-section, solid, max.1.5 mm²
Wire cross-section, solid, max. (AWG)AWG 16
Wire cross-section, solid, min.0.14 mm²
Wire cross-section, solid, min. (AWG)AWG 26

General Data

Air humidity (operation)10% to 95%, non-condensing as per DIN EN 61131-2
Test voltage500 V
UL 94 flammability ratingV-0
Vibration resistance5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6
Air humidity (storage)10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (transport)10% to 95%, non-condensing as per DIN EN 61131-2
Air pressure (operation)≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2
Air pressure (storage)1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Air pressure (transport)1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Pollution severity2
Shock15 g over 11 ms, half sinus wave, acc. to IEC 60068-2-27
Surge voltage categoryII

Power Supply

Current consumption from I25 mA + sensor feed
Reverse polarity protectionYes
Voltage supply24 V DC +20 %/ -15 %, via the system bus

System Data

Configuration interfaceMicro USB 2.0
Diagnostic data1 Bit
Field bus protocolCANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus/TCP, PROFINET IRT, PROFIBUS DP-V1, POWERLINK
Galvanic isolationDC 500 V between current paths
Interfaceu-remote system bus
Module typeAnalogue input module
Parameter data14 Byte
Process data8 Byte
Transmission speed of system bus, max.48 Mbit

Classifications

ETIM 6.0EC001597
ETIM 7.0EC001597
eClass 9.027-24-26-02
eClass 9.127-24-26-02
eClass 10.027-24-26-02

Approvals

ApprovalsABS, BURVER, CE, CULUS, CULUSEX, DEMKOATEX, DNV GL, EAC, IECEXULD, KOREANCERT, LLOYDSREG, RINA, WATEXIECEX
ROHSConform
UL File Number SearchE141197

Documentazione


Altri articoli da WEIDMULLER

Richiedi un preventivo