PRO ECO 960W 24V 40A
- Produttore:
- WEIDMULLER
- Prezzo (IVA esclusa)
- € 230.40
- Codice Nuova Elva
- 1469520000
- Codice produttore
- 1469520000
- Disponibilità
- Invia RdO
Power supply, switch-mode power supply unit, 24 V
Specifications
Depth | 120 mm |
---|---|
Height | 125 mm |
IP Rating | IP20 |
Max. Operating Temperature | 70 °C |
Min. Operating Temperature | -25 °C |
Net Weight | 3,190 g |
Operating Temperature | -25 °C...70 °C |
Storage Temperature | -40 °C...85 °C |
Width | 160 mm |
Dimensions And Weights | |
Width | 160 mm |
Width (inches) | 6.299 inch |
Height | 125 mm |
Height (inches) | 4.921 inch |
Depth | 120 mm |
Depth (inches) | 4.724 inch |
Net weight | 3,190 g |
Temperatures | |
Operating temperature, max. | 70 °C |
Operating temperature, min. | -25 °C |
Storage temperature, max. | 85 °C |
Storage temperature, min. | -40 °C |
Operating temperature | -25 °C...70 °C |
Storage temperature | -40 °C...85 °C |
Environmental Product Compliance | |
REACH SVHC | Lead 7439-92-1 |
Input | |
AC current consumption | 4,6 A @ 230 V AC / 9,9 A @ 110 V AC |
Rated input voltage | 100...240 V AC (wide-range input) |
Recommended back-up fuse | 16 A / DI, safety fuse20 A, Char. B, circuit breaker16 A, Char. C, circuit breaker |
Surge protection | Varistor |
AC input voltage range | 85...264 V AC (derating at 100 V AC) |
Connection system | Screw connection |
DC current consumption | 2,9 A @ 370 V DC / 9 A @ 120 V DC |
DC input voltage range | 80...370 V DC (Derating @ 120 V DC) |
Frequency range AC | 47...63 Hz |
Input frequency | 47...63 Hz |
Input fuse (internal) | Yes |
Inrush current | max. 5 A |
Output | |
Capacitive load | unrestricted |
Ramp-up time | ≤ 100 ms |
Rated output voltage | 24 V DC ± 1 % |
Residual ripple, breaking spikes | < 50 mVPP @ 24 V DC, IN |
Connection system | Screw connection |
Continous output current @ U | 40 A @ 50 °C, 24 A @ 70 °C |
Nominal output current for U | 40 A @ 50 °C |
Output power | 960 W |
Output voltage | 22...28 V (adjustable via potentiometer) |
Overload protection | Yes |
Parallel connection option | yes, max. 3 |
Protection against inverse voltage | Yes |
General Data | |
AC failure bridging time @ I | > 20 ms @ 230 V AC / > 20 ms @ 115 V AC |
Power factor (approx.) | > 0.98…230 V AC / > 0.98…115 V AC |
Power loss, idling | 8 W |
Power loss, nominal load | 85 W |
Protection against over-heating | Yes |
Protection against reverse voltages from the load | 30…35 V DC |
Protection degree | IP20 |
Short-circuit protection | Yes |
Degree of efficiency | 93% |
Earth leakage current, max. | 3.5 mA |
Housing version | Metal, corrosion resistant |
Indication | Green LED (Uoutput > 21.6 V DC), Yellow LED (loutput > 90 % IRated typ. ), red LED (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) |
MTBF | > 500,000 h in accordance with IEC 61709 (SN29500) |
Max. perm. air humidity (operational) | 5 %…95 % RH |
Mounting position, installation notice | on terminal rail TS 35 |
Operating temperature | -25 °C...70 °C |
Emc / Shock / Vibration | |
Limiting of mains voltage harmonic currents | According to EN 61000-3-2 |
Noise emission in accordance with EN55032 | Class B |
Vibration resistance IEC 60068-2-6 | 1 g according to EN 50178 |
Interference immunity test acc. to | EN 61000-4-2 (ESD), EN 61000-4-3 (RS), EN 61000-4-4 (burst), EN 61000-4-5 (surge), EN 61000-4-6 (conducted), EN61000-4-8 (Fields), EN61000-4-11 (Dips) |
Shock resistance IEC 60068-2-27 | 15 g In all directions |
Insulation Coordination | |
Insulation voltage input / earth | 2 kV |
Insulation voltage output / earth | 0.5 kV |
Insulation voltage, input/output | 3 kV |
Pollution severity | 2 |
Protection class | I, with PE connection |
Electrical Safety (Applied Standards) | |
Electrical machine equipment | Acc. to EN60204 |
For use with electronic equipment | Acc. to EN50178 / VDE0160 |
Protection against dangerous shock currents | Acc. to VDE0106-101 |
Protective separation / protection against electrical shock | VDE0100-410 / acc. to DIN57100-410 |
Safety extra-low voltage | SELV according to EN 60950, PELV according to EN 60204 |
Safety transformers for switch-mode power supplies | According to EN 61558-2-16 |
Connection Data (Input) | |
Conductor cross-section, AWG/kcmil , max. | 12 |
Wire connection cross section, flexible (input), max. | 2.5 mm² |
Conductor cross-section, AWG/kcmil , min. | 26 |
Conductor cross-section, flexible , min. | 0.5 mm² |
Conductor cross-section, rigid , max. | 6 mm² |
Conductor cross-section, rigid , min. | 0.5 mm² |
Connection system | Screw connection |
Number of terminals | 3 for L/N/PE |
Tightening torque, max. | 0.6 Nm |
Tightening torque, min. | 0.5 Nm |
Connection Data (Output) | |
Conductor cross-section, AWG/kcmil , max. | 8 |
Tightening torque, min. | 0.5 Nm |
Conductor cross-section, AWG/kcmil , min. | 22 |
Conductor cross-section, flexible , max. | 10 mm² |
Conductor cross-section, flexible , min. | 2.5 mm² |
Conductor cross-section, rigid , max. | 16 mm² |
Conductor cross-section, rigid , min. | 0.5 mm² |
Connection system | Screw connection |
Number of terminals | 7 (++,---,13,14) |
Tightening torque, max. | 0.6 Nm |
Signalling | |
Contact load (NO contact) | max. 30 V DC / 1 A |
Floating contact | Yes |
Relay on/off | Output voltage >21.6 V DC/ <20.4 V DC, overload |
Approvals | |
Approvals | CE, CULUS, EAC, TUEV |
ROHS | Conform |
UL File Number Search | E258476 |
Ratings Iecex/Atex/Cul | |
Certificate no. (cULus) | E258476 |
Classifications | |
ETIM 6.0 | EC002540 |
ETIM 7.0 | EC002540 |
eClass 9.0 | 27-04-07-01 |
eClass 9.1 | 27-04-07-01 |
eClass 10.0 | 27-04-07-01 |