ACT20P-CI-VO-P
- Produttore:
- WEIDMULLER
- Prezzo (IVA esclusa)
- € 137.61
- Codice Nuova Elva
- 2489740000
- Codice produttore
- 2489740000
- Disponibilità
- 2 in stock
Signal converter/isolator, Input : 0(4)-20 mA, Output : 0-10 V
Specifications
Depth | 113.7 mm |
---|---|
Height | 127.1 mm |
Max. Operating Temperature | 60 °C |
Min. Operating Temperature | -20 °C |
Net Weight | 120 g |
Operating Temperature | -20 °C...60 °C |
Storage Temperature | -40 °C...85 °C |
Weight | 110 g |
Width | 0.492 in |
Dimensions And Weights | |
Width | 12.5 mm |
Width (inches) | 0.492 inch |
Height | 127.1 mm |
Height (inches) | 5.004 inch |
Depth | 113.7 mm |
Depth (inches) | 4.476 inch |
Weight | 110 g |
Net weight | 120 g |
Temperatures | |
Humidity | 5...95 %, no condensation |
Operating temperature, max. | 60 °C |
Operating temperature, min. | -20 °C |
Storage temperature, max. | 85 °C |
Storage temperature, min. | -40 °C |
Operating temperature | -20 °C...60 °C |
Storage temperature | -40 °C...85 °C |
Environmental Product Compliance | |
REACH SVHC | Lead 7439-92-1 |
Input | |
Number of inputs | 1 |
Sensor supply | > 17 V DC at 20 mA |
Input signal | 2-/3-wire transmitter, Current source |
Input current | 0...20 mA, 4…20mA |
Voltage drop | ≤ 1 V |
Output | |
Number of outputs | 1 |
Output voltage, note | 0…10 V (if input: 0…20 mA), 2…10 V (if input: 4…20 mA) |
load impedance voltage | ≥ 600 kΩ |
General Data | |
Accuracy | ±0,1 % FSR max., 0,05 % FSR typ. |
Configuration | none |
Current consumption | ≤60 mA (24V power supply, 20mA output) |
Galvanic isolation | 3-way isolator, between input ⁄ output ⁄ supply |
Rail | TS 35 |
Step response time | ≤ 0,5 ms |
Temperature coefficient | 80 ppm/K |
Voltage supply | 20…30 V DC |
Insulation Coordination | |
EMC standards | EN 61326-1 |
Galvanic isolation | 3-way isolator, between input ⁄ output ⁄ supply |
Impulse withstand voltage | 4 kV (1.2/50 µs) |
Insulation voltage | 2 kV inputs / outputs / power supply |
Pollution severity | 2 |
Surge voltage category | III |
Connection Data | |
Type of connection | PUSH IN |
Wire connection cross section AWG, min. | AWG 26 |
Wire connection cross section AWG, max. | AWG 14 |
Wire cross-section, solid, min. | 0.2 mm² |
Wire cross-section, solid, max. | 2.5 mm² |
Wire connection cross-section, finely stranded, min. | 0.2 mm² |
Wire connection cross section, finely stranded, max. | 2.5 mm² |
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. | 0.2 mm² |
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. | 2.5 mm² |
Product Information | |
Product information | The fixed DC repeater ACT20P-CI-VO isolates analogue standard current signals from a power source or from a 2- or 3-wire sensor. An analogue input current signal is converted linear and galvanic isolated into an analogue output voltage signal. The power supply is galvanically isolated from input and output (3-way isolation). Features The active or passive mA current signal inputs are completely electrically isolated. Front LED indicates operation status. 3-way galvanic isolation between input, output and power supply |
Classifications | |
ETIM 6.0 | EC002653 |
ETIM 7.0 | EC002653 |
eClass 9.0 | 27-21-01-20 |
eClass 9.1 | 27-21-01-90 |
eClass 10.0 | 27-21-01-20 |