AF52-30-00-13 100-250V50/60HZ-DC Contactor
- Manufactured by:
- ABB
The AF52-30-00-13 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 22 kW / 400 V AC (AC-3) or 40 hp / 480 V UL and switching power circuits up to 100 A (AC-1) or 80 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Specifications
Ordering | |
---|---|
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85364900 |
Dimensions | |
Product Net Width | 55 mm |
Product Net Depth / Length | 111 mm |
Product Net Height | 125.5 mm |
Product Net Weight | 0.95 kg |
Technical | |
Rated Operational Voltage | Main Circuit 690 V |
Rated Frequency (f) | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 105 A |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 100(690 V) 60 °C 80 A(690 V) 70 °C 70 |
Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 53 A(440 V) 60 °C 53 A(500 V) 60 °C 45 A(690 V) 60 °C 35 A(380 / 400 V) 60 °C 53 A(220 / 230 / 240 V) 60 °C 53 A |
Rated Operational Power AC-3 (Pe) | (400 V) 22 kW(415 V) 30 kW(440 V) 30 kW(500 V) 30 kW(690 V) 30 kW(380 / 400 V) 22 kW(220 / 230 / 240 V) 15 kW |
Rated Short-time Withstand Current (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 Afor 1 s -empty- A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A |
Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 1200 cycles per hour |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | 6 kV |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V50 Hz / 60 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V |
Operate Time | Between Coil De-energization and NC Contact Closing 19 ... 105 msBetween Coil De-energization and NO Contact Opening 17 ... 100 msBetween Coil Energization and NC Contact Opening 38 ... 95 msBetween Coil Energization and NO Contact Closing 42 ... 100 ms |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 4 ... 35 mm²Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²Rigid 1/2x 6 ... 3 5 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid 1/2x 1 ... 2.5 mm² |
Wire Stripping Length | Main Circuit 16 mm |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
Terminal Type | Screw Terminals |
Number of Main Contacts NO | 3 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 0 |
Number of Auxiliary Contacts NC | 0 |
Technical UL/CSA | |
General Use Rating UL/CSA | (600 V AC) 80 A |
Horsepower Rating UL/CSA | (120 V AC) Single Phase 3 hp(200 ... 208 V AC) Three Phase 15 hp(220 ... 240 V AC) Three Phase 20 hp(240 V AC) Single Phase 10 hp(440 ... 480 V AC) Three Phase 40 hp(550 ... 600 V AC) Three Phase 50 hp |
Tightening Torque UL/CSA | Control Circuit 11 IAMain Circuit 35 IA |
Environmental | |
Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °CClose to Contactor without Thermal O/L Relay -40 ... +70 °CClose to Contactor for Storage -60 ... +80 °C |
Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible | 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6 | 5 ... 300 Hz 3 g closed position / 3 g open position |
Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: A 25 K40Closed, Shock Direction: B1 25 K40Closed, Shock Direction: B2 15 K40Closed, Shock Direction: C1 25 K40Closed, Shock Direction: C2 25 K40Open, Shock Direction: B1 5 K40 |
RoHS Status | Following EU Directive 2011/65/EU |
Container Information | |
Package Level 1 Units | box 1 piece |
Package Level 1 Width | 150 mm |
Package Level 1 Depth / Length | 150 mm |
Package Level 1 Height | 97 mm |
Package Level 1 Gross Weight | 1.05 kg |
Package Level 1 EAN | 3471523132337 |
Package Level 2 Units | box 10 piece |
Package Level 2 Width | 250 mm |
Package Level 2 Depth / Length | 300 mm |
Package Level 2 Height | 300 mm |
Package Level 2 Gross Weight | 10.5 kg |
Package Level 3 Units | 240 piece |
Classifications | |
Object Classification Code | Q |
ETIM 4 | EC000066 - Magnet contactor, AC-switching |
ETIM 5 | EC000066 - Magnet contactor, AC-switching |
eClass | V11.0 : 27371003 |
E-Number (Finland) | 3707016 |
E-Number (Sweden) | 3210039 |