CPU315F, 384KB
- Manufactured by:
- SIEMENS
- Price (VAT excluded)
- € 2706.30
- Nuova Elva code
- 6ES73156FF040AB0
- Manufacturer code
- 6ES7315-6FF04-0AB0
- Availability
- Send request for quotation
SIMATIC S7-300, CPU 315F-2DP Fail-safe module with MPI Integr. power supply 24 V DC, Work memory 384 KB, 40 mm width, 2nd interface DP master/slave Micro Memory Card required
Specifications
Depth | 130 mm |
---|---|
Height | 125 mm |
Weight | 290 g |
Width | 40 mm |
Specifications | |
Number Of Industrial Ethernet Interfaces | 0 |
Number Of Profinet Interfaces | 0 |
Number Of Rs 485 Interfaces | 2 |
Number Of Rs 422 Interfaces | 0 |
Number | Unlimited (Limited Only By Ram Capacity) |
General information | |
Hw Functional Status | 1 |
Firmware Version | V3.3 |
Engineering with | |
Programming Package | Step 7 V5.5 + Sp1 Or Higher Or Step 7 V5.2 + Sp1 Or Higher With Hsp 218 + Distributed Safety |
Supply voltage Rated value (DC) | |
24 V Dc | Yes |
Permissible Range, Lower Limit (Dc) | 19.2 V |
Permissible Range, Upper Limit (Dc) | 28.8 V |
External Protection For Power Supply Lines (Recommendation) | 2 A Min. |
Mains buffering | |
Mains/Voltage Failure Stored Energy Time | 5 Ms |
Repeat Rate, Min. | 1 S |
Input current | |
Current Consumption (Rated Value) | 850 Ma |
Current Consumption (In No-Load Operation), Typ. | 150 Ma |
Inrush Current, Typ. | 3.5 A |
I²T | 1 A²·S |
Work memory | |
Integrated | 384 Kbyte |
Expandable | No |
Size Of Retentive Memory For Retentive Data Blocks | 128 Kbyte |
Load memory | |
Plug-In (Mmc) | Yes |
Plug-In (Mmc), Max. | 8 Mbyte |
Data Management On Mmc (After Last Programming), Min. | 10 Y |
Backup | |
Present | Yes; Guaranteed By Mmc (Maintenance-Free) |
Without Battery | Yes; Program And Data |
CPU processing times | |
For Bit Operations, Typ. | 0.05 Μs |
For Word Operations, Typ. | 0.09 Μs |
For Fixed Point Arithmetic, Typ. | 0.12 Μs |
For Floating Point Arithmetic, Typ. | 0.45 Μs |
CPU-blocks | |
Number Of Blocks (Total) | 1 024; (Dbs, Fcs, Fbs); The Maximum Number Of Loadable Blocks Can Be Reduced By The Mmc Used. |
DB | |
Number, Max. | 1 024; Number Range: 1 To 16000 |
Size, Max. | 64 Kbyte |
FB | |
Number, Max. | 1 024; Number Range: 0 To 7999 |
Size, Max. | 64 Kbyte |
FC | |
Number, Max. | 1 024; Number Range: 0 To 7999 |
Size, Max. | 64 Kbyte |
OB | |
Description | See Instruction List |
Size, Max. | 64 Kbyte |
Number Of Free Cycle Obs | 1; Ob 1 |
Number Of Time Alarm Obs | 1; Ob 10 |
Number Of Delay Alarm Obs | 2; Ob 20, 21 |
Number Of Cyclic Interrupt Obs | 4; Ob 32, 33, 34, 35 |
Number Of Process Alarm Obs | 1; Ob 40 |
Number Of Dpv1 Alarm Obs | 3; Ob 55, 56, 57 |
Number Of Isochronous Mode Obs | 1; Ob 61 |
Number Of Startup Obs | 1; Ob 100 |
Number Of Asynchronous Error Obs | 5; Ob 80, 82, 85, 86, 87 |
Number Of Synchronous Error Obs | 2; Ob 121, 122 |
Nesting depth | |
Per Priority Class | 16 |
Additional Within An Error Ob | 4 |
S7 counter | |
Number | 256 |
Retentivity | |
Adjustable | Yes |
Lower Limit | 0 |
Upper Limit | 255 |
Preset | Z 0 To Z 7 |
Adjustable | Yes |
Lower Limit | 0 |
Upper Limit | 255 |
Preset | No Retentivity |
Counting range | |
Lower Limit | 0 |
Upper Limit | 999 |
S7 times | |
Number | 256 |
Time range | |
Lower Limit | 10 Ms |
Upper Limit | 9 990 S |
IEC timer | |
Present | Yes |
Type | Sfb |
Number | Unlimited (Limited Only By Ram Capacity) |
Data areas and their retentivity | |
Retentive Data Area In Total | All, 128 Kb Max. |
Flag | |
Number, Max. | 2 048 Byte |
Retentivity Available | Yes; Mb 0 To Mb 2047 |
Retentivity Preset | Mb 0 To Mb 15 |
Number Of Clock Memories | 8; 1 Memory Byte |
Data blocks | |
Retentivity Adjustable | Yes; Via Non-Retain Property On Db |
Retentivity Preset | Yes |
Local data | |
Per Priority Class, Max. | 32 Kbyte; Max. 2 Kb Per Block |
I/O address area | |
Inputs | 2 048 Byte |
Outputs | 2 048 Byte |
Of which distributed | |
Inputs | 2 048 Byte |
Outputs | 2 048 Byte |
Process image | |
Inputs | 2 048 Byte |
Outputs | 2 048 Byte |
Inputs, Adjustable | 2 048 Byte |
Outputs, Adjustable | 2 048 Byte |
Inputs, Default | 384 Byte |
Outputs, Default | 384 Byte |
Subprocess images | |
Number Of Subprocess Images, Max. | 1 |
Digital channels | |
Inputs | 16 384 |
Of Which Central | 1 024 |
Outputs | 16 384 |
Of Which Central | 1 024 |
Analog channels | |
Inputs | 1 024 |
Of Which Central | 256 |
Outputs | 1 024 |
Of Which Central | 256 |
Hardware configuration | |
Number Of Expansion Units, Max. | 3 |
Number of DP masters | |
Integrated | 1 |
Via Cp | 4 |
Number of operable FMs and CPs (recommended) | |
Fm | 8 |
Cp, Ptp | 8 |
Cp, Lan | 10 |
Rack | |
Racks, Max. | 4 |
Modules Per Rack, Max. | 8 |
Clock | |
Hardware Clock (Real-Time) | Yes |
Retentive And Synchronizable | Yes |
Backup Time | 6 Wk; At 40 °C Ambient Temperature |
Deviation Per Day, Max. | 10 S; Typ.: 2 S |
Behavior Of The Clock Following Power-On | Clock Continues Running After Power Off |
Behavior Of The Clock Following Expiry Of Backup Period | Clock Continues To Run With The Time At Which The Power Failure Occurred |
Operating hours counter | |
Number | 1 |
Number/Number Range | 0 |
Range Of Values | 0 To 2^31 Hours (When Using Sfc 101) |
Retentive | Yes; Must Be Restarted At Each Restart |
Clock synchronization | |
Supported | Yes |
To Mpi, Master | Yes |
To Mpi, Slave | Yes |
To Dp, Master | Yes; With Dp Slave Only Slave Clock |
To Dp, Slave | Yes |
In As, Master | Yes |
In As, Slave | No |
Digital inputs | |
Number Of Digital Inputs | 0 |
Digital outputs | |
Number Of Digital Outputs | 0 |
Analog inputs | |
Number Of Analog Inputs | 0 |
Analog outputs | |
Number Of Analog Outputs | 0 |
1. Interface | |
Interface Type | Integrated Rs 485 Interface |
Physics | Rs 485 |
Isolated | No |
Power Supply To Interface (15 To 30 V Dc), Max. | 200 Ma |
Functionality | |
Mpi | Yes |
Profibus Dp Master | No |
Profibus Dp Slave | No |
Point-To-Point Connection | No |
Mpi | No |
Profibus Dp Master | Yes |
Profibus Dp Slave | Yes |
Point-To-Point Connection | No |
MPI | |
Transmission Rate, Max. | 187.5 Kbit/S |
Services | |
Pg/Op Communication | Yes |
Routing | Yes |
Global Data Communication | Yes |
S7 Basic Communication | Yes |
S7 Communication | Yes; Only Server, Configured On One Side |
S7 Communication, As Client | No |
S7 Communication, As Server | Yes |
Pg/Op Communication | Yes |
Routing | Yes |
Global Data Communication | No |
S7 Basic Communication | Yes; I Blocks Only |
S7 Communication | Yes; Only Server, Configured On One Side |
S7 Communication, As Client | No |
S7 Communication, As Server | Yes |
Equidistance | Yes |
Isochronous Mode | Yes; Ob 61 |
Sync/Freeze | Yes |
Activation/Deactivation Of Dp Slaves | Yes |
Number Of Dp Slaves That Can Be Simultaneously Activated/Deactivated, Max. | 8 |
Dpv1 | Yes |
Pg/Op Communication | Yes |
Routing | Yes; Only With Active Interface |
Global Data Communication | No |
S7 Basic Communication | No |
S7 Communication | Yes; Only Server, Configured On One Side |
S7 Communication, As Client | No |
S7 Communication, As Server | Yes |
Direct Data Exchange (Slave-To-Slave Communication) | Yes |
Dpv1 | No |
2. Interface | |
Interface Type | Integrated Rs 485 Interface |
Physics | Rs 485 |
Isolated | Yes |
Power Supply To Interface (15 To 30 V Dc), Max. | 200 Ma |
DP master | |
Transmission Rate, Max. | 12 Mbit/S |
Number Of Dp Slaves, Max. | 124; Per Station |
Address area | |
Inputs, Max. | 2 048 Byte |
Outputs, Max. | 2 048 Byte |
User data per DP slave | |
Inputs, Max. | 244 Byte |
Outputs, Max. | 244 Byte |
DP slave | |
Gsd File | The Latest Gsd File Is Available At: Http://Www.Siemens.Com/Profibus-Gsd |
Transmission Rate, Max. | 12 Mbit/S |
Automatic Baud Rate Search | Yes; Only With Passive Interface |
Address Area, Max. | 32 |
User Data Per Address Area, Max. | 32 Byte |
Transfer memory | |
Inputs | 244 Byte |
Outputs | 244 Byte |
Isochronous mode | |
Isochronous Operation (Application Synchronized Up To Terminal) | Yes |
Communication functions | |
Pg/Op Communication | Yes |
Data Record Routing | Yes |
Global data communication | |
Supported | Yes |
Number Of Gd Loops, Max. | 8 |
Number Of Gd Packets, Max. | 8 |
Number Of Gd Packets, Transmitter, Max. | 8 |
Number Of Gd Packets, Receiver, Max. | 8 |
Size Of Gd Packets, Max. | 22 Byte |
Size Of Gd Packet (Of Which Consistent), Max. | 22 Byte |
S7 basic communication | |
Supported | Yes |
User Data Per Job, Max. | 76 Byte |
User Data Per Job (Of Which Consistent), Max. | 76 Byte; 76 Bytes (With X_Send Or X_Rcv); 64 Bytes (With X_Put Or X_Get As Server) |
S7 communication | |
Supported | Yes |
As Server | Yes |
As Client | Yes; Via Cp And Loadable Fb |
User Data Per Job, Max. | 180 Byte; With Put/Get |
User Data Per Job (Of Which Consistent), Max. | 240 Byte; As Server |
S5 compatible communication | |
Supported | Yes; Via Cp And Loadable Fc |
Number of connections | |
Overall | 16 |
Usable For Pg Communication | 15 |
Reserved For Pg Communication | 1 |
Adjustable For Pg Communication, Min. | 1 |
Adjustable For Pg Communication, Max. | 15 |
Usable For Op Communication | 15 |
Reserved For Op Communication | 1 |
Adjustable For Op Communication, Min. | 1 |
Adjustable For Op Communication, Max. | 15 |
Usable For S7 Basic Communication | 12 |
Reserved For S7 Basic Communication | 0 |
Adjustable For S7 Basic Communication, Min. | 0 |
Adjustable For S7 Basic Communication, Max. | 12 |
S7 message functions | |
Number Of Login Stations For Message Functions, Max. | 16; Depending On The Configured Connections For Pg/Op And S7 Basic Communication |
Process Diagnostic Messages | Yes |
Simultaneously Active Alarm-S Blocks, Max. | 300 |
Test commissioning functions | |
Status Block | Yes; Up To 2 Simultaneously |
Single Step | Yes |
Number Of Breakpoints | 4 |
Status/control | |
Status/Control Variable | Yes |
Variables | Inputs, Outputs, Memory Bits, Db, Times, Counters |
Number Of Variables, Max. | 30 |
Of Which Status Variables, Max. | 30 |
Of Which Control Variables, Max. | 14 |
Forcing | |
Forcing | Yes |
Forcing, Variables | Inputs, Outputs |
Number Of Variables, Max. | 10 |
Diagnostic buffer | |
Present | Yes |
Number Of Entries, Max. | 500 |
Adjustable | No |
Of Which Powerfail-Proof | 100; Only The Last 100 Entries Are Retained |
Can Be Set | Yes; From 10 To 499 |
Preset | 10 |
Service data | |
Can Be Read Out | Yes |
Ambient temperature during operation | |
Min. | 0 °C |
Max. | 60 °C |
Configuration software | |
Step 7 | Yes; V5.2 Sp1 Or Higher With Hw Update |
Programming | |
Command Set | See Instruction List |
Nesting Levels | 8 |
System Functions (Sfc) | See Instruction List |
System Function Blocks (Sfb) | See Instruction List |
Programming language | |
Lad | Yes |
Fbd | Yes |
Stl | Yes |
Scl | Yes |
Cfc | Yes |
Graph | Yes |
Higraph® | Yes |
Know-how protection | |
User Program Protection/Password Protection | Yes |
Block Encryption | Yes; With S7 Block Privacy |
Dimensions | |
Width | 40 Mm |
Height | 125 Mm |
Depth | 130 Mm |
Weights | |
Weight, Approx. | 290 G |