CPU315F, 384KB

Produttore:
SIEMENS
Siemens

A53c8de6eab8f50ea0dccb00cb4a59acf3947f1e medium
Prezzo (IVA esclusa)
€ 2706.30
Codice Nuova Elva
6ES73156FF040AB0
Codice produttore
6ES7315-6FF04-0AB0
Disponibilità
Invia RdO

SIMATIC S7-300, CPU 315F-2DP Fail-safe module with MPI Integr. power supply 24 V DC, Work memory 384 KB, 40 mm width, 2nd interface DP master/slave Micro Memory Card required

Specifications

Depth130 mm
Height125 mm
Weight290 g
Width40 mm

Specifications

Number Of Industrial Ethernet Interfaces0
Number Of Profinet Interfaces0
Number Of Rs 485 Interfaces2
Number Of Rs 422 Interfaces0
NumberUnlimited (Limited Only By Ram Capacity)

General information

Hw Functional Status1
Firmware VersionV3.3

Engineering with

Programming PackageStep 7 V5.5 + Sp1 Or Higher Or Step 7 V5.2 + Sp1 Or Higher With Hsp 218 + Distributed Safety

Supply voltage Rated value (DC)

24 V DcYes
Permissible Range, Lower Limit (Dc)19.2 V
Permissible Range, Upper Limit (Dc)28.8 V
External Protection For Power Supply Lines (Recommendation)2 A Min.

Mains buffering

Mains/Voltage Failure Stored Energy Time5 Ms
Repeat Rate, Min.1 S

Input current

Current Consumption (Rated Value)850 Ma
Current Consumption (In No-Load Operation), Typ.150 Ma
Inrush Current, Typ.3.5 A
I²T1 A²·S

Work memory

Integrated384 Kbyte
ExpandableNo
Size Of Retentive Memory For Retentive Data Blocks128 Kbyte

Load memory

Plug-In (Mmc)Yes
Plug-In (Mmc), Max.8 Mbyte
Data Management On Mmc (After Last Programming), Min.10 Y

Backup

PresentYes; Guaranteed By Mmc (Maintenance-Free)
Without BatteryYes; Program And Data

CPU processing times

For Bit Operations, Typ.0.05 Μs
For Word Operations, Typ.0.09 Μs
For Fixed Point Arithmetic, Typ.0.12 Μs
For Floating Point Arithmetic, Typ.0.45 Μs

CPU-blocks

Number Of Blocks (Total)1 024; (Dbs, Fcs, Fbs); The Maximum Number Of Loadable Blocks Can Be Reduced By The Mmc Used.

DB

Number, Max.1 024; Number Range: 1 To 16000
Size, Max.64 Kbyte

FB

Number, Max.1 024; Number Range: 0 To 7999
Size, Max.64 Kbyte

FC

Number, Max.1 024; Number Range: 0 To 7999
Size, Max.64 Kbyte

OB

DescriptionSee Instruction List
Size, Max.64 Kbyte
Number Of Free Cycle Obs1; Ob 1
Number Of Time Alarm Obs1; Ob 10
Number Of Delay Alarm Obs2; Ob 20, 21
Number Of Cyclic Interrupt Obs4; Ob 32, 33, 34, 35
Number Of Process Alarm Obs1; Ob 40
Number Of Dpv1 Alarm Obs3; Ob 55, 56, 57
Number Of Isochronous Mode Obs1; Ob 61
Number Of Startup Obs1; Ob 100
Number Of Asynchronous Error Obs5; Ob 80, 82, 85, 86, 87
Number Of Synchronous Error Obs2; Ob 121, 122

Nesting depth

Per Priority Class16
Additional Within An Error Ob4

S7 counter

Number256

Retentivity

AdjustableYes
Lower Limit0
Upper Limit255
PresetZ 0 To Z 7
AdjustableYes
Lower Limit0
Upper Limit255
PresetNo Retentivity

Counting range

Lower Limit0
Upper Limit999

S7 times

Number256

Time range

Lower Limit10 Ms
Upper Limit9 990 S

IEC timer

PresentYes
TypeSfb
NumberUnlimited (Limited Only By Ram Capacity)

Data areas and their retentivity

Retentive Data Area In TotalAll, 128 Kb Max.

Flag

Number, Max.2 048 Byte
Retentivity AvailableYes; Mb 0 To Mb 2047
Retentivity PresetMb 0 To Mb 15
Number Of Clock Memories8; 1 Memory Byte

Data blocks

Retentivity AdjustableYes; Via Non-Retain Property On Db
Retentivity PresetYes

Local data

Per Priority Class, Max.32 Kbyte; Max. 2 Kb Per Block

I/O address area

Inputs2 048 Byte
Outputs2 048 Byte

Of which distributed

Inputs2 048 Byte
Outputs2 048 Byte

Process image

Inputs2 048 Byte
Outputs2 048 Byte
Inputs, Adjustable2 048 Byte
Outputs, Adjustable2 048 Byte
Inputs, Default384 Byte
Outputs, Default384 Byte

Subprocess images

Number Of Subprocess Images, Max.1

Digital channels

Inputs16 384
Of Which Central1 024
Outputs16 384
Of Which Central1 024

Analog channels

Inputs1 024
Of Which Central256
Outputs1 024
Of Which Central256

Hardware configuration

Number Of Expansion Units, Max.3

Number of DP masters

Integrated1
Via Cp4

Number of operable FMs and CPs (recommended)

Fm8
Cp, Ptp8
Cp, Lan10

Rack

Racks, Max.4
Modules Per Rack, Max.8

Clock

Hardware Clock (Real-Time)Yes
Retentive And SynchronizableYes
Backup Time6 Wk; At 40 °C Ambient Temperature
Deviation Per Day, Max.10 S; Typ.: 2 S
Behavior Of The Clock Following Power-OnClock Continues Running After Power Off
Behavior Of The Clock Following Expiry Of Backup PeriodClock Continues To Run With The Time At Which The Power Failure Occurred

Operating hours counter

Number1
Number/Number Range0
Range Of Values0 To 2^31 Hours (When Using Sfc 101)
RetentiveYes; Must Be Restarted At Each Restart

Clock synchronization

SupportedYes
To Mpi, MasterYes
To Mpi, SlaveYes
To Dp, MasterYes; With Dp Slave Only Slave Clock
To Dp, SlaveYes
In As, MasterYes
In As, SlaveNo

Digital inputs

Number Of Digital Inputs0

Digital outputs

Number Of Digital Outputs0

Analog inputs

Number Of Analog Inputs0

Analog outputs

Number Of Analog Outputs0

1. Interface

Interface TypeIntegrated Rs 485 Interface
PhysicsRs 485
IsolatedNo
Power Supply To Interface (15 To 30 V Dc), Max.200 Ma

Functionality

MpiYes
Profibus Dp MasterNo
Profibus Dp SlaveNo
Point-To-Point ConnectionNo
MpiNo
Profibus Dp MasterYes
Profibus Dp SlaveYes
Point-To-Point ConnectionNo

MPI

Transmission Rate, Max.187.5 Kbit/S

Services

Pg/Op CommunicationYes
RoutingYes
Global Data CommunicationYes
S7 Basic CommunicationYes
S7 CommunicationYes; Only Server, Configured On One Side
S7 Communication, As ClientNo
S7 Communication, As ServerYes
Pg/Op CommunicationYes
RoutingYes
Global Data CommunicationNo
S7 Basic CommunicationYes; I Blocks Only
S7 CommunicationYes; Only Server, Configured On One Side
S7 Communication, As ClientNo
S7 Communication, As ServerYes
EquidistanceYes
Isochronous ModeYes; Ob 61
Sync/FreezeYes
Activation/Deactivation Of Dp SlavesYes
Number Of Dp Slaves That Can Be Simultaneously Activated/Deactivated, Max.8
Dpv1Yes
Pg/Op CommunicationYes
RoutingYes; Only With Active Interface
Global Data CommunicationNo
S7 Basic CommunicationNo
S7 CommunicationYes; Only Server, Configured On One Side
S7 Communication, As ClientNo
S7 Communication, As ServerYes
Direct Data Exchange (Slave-To-Slave Communication)Yes
Dpv1No

2. Interface

Interface TypeIntegrated Rs 485 Interface
PhysicsRs 485
IsolatedYes
Power Supply To Interface (15 To 30 V Dc), Max.200 Ma

DP master

Transmission Rate, Max.12 Mbit/S
Number Of Dp Slaves, Max.124; Per Station

Address area

Inputs, Max.2 048 Byte
Outputs, Max.2 048 Byte

User data per DP slave

Inputs, Max.244 Byte
Outputs, Max.244 Byte

DP slave

Gsd FileThe Latest Gsd File Is Available At: Http://Www.Siemens.Com/Profibus-Gsd
Transmission Rate, Max.12 Mbit/S
Automatic Baud Rate SearchYes; Only With Passive Interface
Address Area, Max.32
User Data Per Address Area, Max.32 Byte

Transfer memory

Inputs244 Byte
Outputs244 Byte

Isochronous mode

Isochronous Operation (Application Synchronized Up To Terminal)Yes

Communication functions

Pg/Op CommunicationYes
Data Record RoutingYes

Global data communication

SupportedYes
Number Of Gd Loops, Max.8
Number Of Gd Packets, Max.8
Number Of Gd Packets, Transmitter, Max.8
Number Of Gd Packets, Receiver, Max.8
Size Of Gd Packets, Max.22 Byte
Size Of Gd Packet (Of Which Consistent), Max.22 Byte

S7 basic communication

SupportedYes
User Data Per Job, Max.76 Byte
User Data Per Job (Of Which Consistent), Max.76 Byte; 76 Bytes (With X_Send Or X_Rcv); 64 Bytes (With X_Put Or X_Get As Server)

S7 communication

SupportedYes
As ServerYes
As ClientYes; Via Cp And Loadable Fb
User Data Per Job, Max.180 Byte; With Put/Get
User Data Per Job (Of Which Consistent), Max.240 Byte; As Server

S5 compatible communication

SupportedYes; Via Cp And Loadable Fc

Number of connections

Overall16
Usable For Pg Communication15
Reserved For Pg Communication1
Adjustable For Pg Communication, Min.1
Adjustable For Pg Communication, Max.15
Usable For Op Communication15
Reserved For Op Communication1
Adjustable For Op Communication, Min.1
Adjustable For Op Communication, Max.15
Usable For S7 Basic Communication12
Reserved For S7 Basic Communication0
Adjustable For S7 Basic Communication, Min.0
Adjustable For S7 Basic Communication, Max.12

S7 message functions

Number Of Login Stations For Message Functions, Max.16; Depending On The Configured Connections For Pg/Op And S7 Basic Communication
Process Diagnostic MessagesYes
Simultaneously Active Alarm-S Blocks, Max.300

Test commissioning functions

Status BlockYes; Up To 2 Simultaneously
Single StepYes
Number Of Breakpoints4

Status/control

Status/Control VariableYes
VariablesInputs, Outputs, Memory Bits, Db, Times, Counters
Number Of Variables, Max.30
Of Which Status Variables, Max.30
Of Which Control Variables, Max.14

Forcing

ForcingYes
Forcing, VariablesInputs, Outputs
Number Of Variables, Max.10

Diagnostic buffer

PresentYes
Number Of Entries, Max.500
AdjustableNo
Of Which Powerfail-Proof100; Only The Last 100 Entries Are Retained
Can Be SetYes; From 10 To 499
Preset10

Service data

Can Be Read OutYes

Ambient temperature during operation

Min.0 °C
Max.60 °C

Configuration software

Step 7Yes; V5.2 Sp1 Or Higher With Hw Update

Programming

Command SetSee Instruction List
Nesting Levels8
System Functions (Sfc)See Instruction List
System Function Blocks (Sfb)See Instruction List

Programming language

LadYes
FbdYes
StlYes
SclYes
CfcYes
GraphYes
Higraph®Yes

Know-how protection

User Program Protection/Password ProtectionYes
Block EncryptionYes; With S7 Block Privacy

Dimensions

Width40 Mm
Height125 Mm
Depth130 Mm

Weights

Weight, Approx.290 G

Documentazione