Motion servo drive, Lexium 32, three phase supply voltage 208/480 V, 3 kW

Manufactured by:
Schneider Electric
Schneider%20electric

97b381bb1f6d42cc94577c3bd10d2316885bf8e6 medium
Price (VAT excluded)
€ 1234.09
Nuova Elva code
LXM32AD30N4
Manufacturer code
LXM32AD30N4
Availability
Send request for quotation

This product is part of the Lexium 32 range, an offer of motion servo drives for machines from 0.15kW to 7kW. The AC motion servo drive for one axis, features with an integrated EMC filter, compact drive with analogue inputs and pulse train. It provides 1 capture, 2 safety, 4 logic discrete inputs and 2 discrete outputs. Thanks to its compact design this servo drive enables to save on cabinet space and size, reduces the machine footprint and decreases costs. It is a motion servo drive with a rated supply voltage of 200V to 240V, 380V to 480V (three phase), a continuous output current of 10A at 8kHz and a continuous power of 5600W at 400V. It is furnished with terminal for electrical connection and three RJ45 connectors for CANmotion, CANopen, and Modbus, integrated communication interfaces. It is an IP20 rated product. Its dimensions are 68mm (Width) x 237mm (Depth) x 270mm (Height). It weighs 2.6kg. This product is certified by CE, CSA, RoHS, TUV and UL. It meets EN/IEC 61800-3 and EN/IEC 61800-5-1 standards. This product is compatible with servo motors BMH and BSH. Servo drive range with four servo drive models and two servo motor families plus an intelligent selection of options. It provides you with the drive and motor combination that has exactly the right power, performance and functionality.

Specifications

CertificationsCSA
Depth237 mm
Height270 mm
Net Weight2.6 kg
Number of Phases3
StandardEN/IEC 61800-3
Storage Temperature-25-70 °C
Warranty Length18 months
Width68 mm

Specifications

Network Frequency47.5...63 Hz
Emc Filterintegrated
Nominal Power2 kW 230 V 8 kHz || 3 kW 400 V 8 kHz
Continuous Output Current10 A 8 kHz
Continuous Power2600 W 230 V || 5600 W 400 V
Device Short NameLXM32A
Supply Frequency50/60 Hz - 5...5 %
[Us] Rated Supply Voltage200...240 V - 15...10 % || 380...480 V - 15...10 %
Output Current 3S Peak30 A 5 s
Range Of ProductLexium 32
Format Of The Drivebook
Product Or Component Typemotion servo drive
Phasethree phase
Line Current11.6 A 74 % 380 V, with external line choke 1 mH || 9.6 A 85 % 480 V, with external line choke 1 mH || 7 A 152 % 480 V, without line choke || 9.8 A 146 % 380 V, without line choke
Supply Voltage Limits170-264 V || 323-528 V

Contractual warranty

Warranty18 months

Complementary

Product Compatibilityservo motor BMH 100 mm, 3 || servo motor BMH 140 mm, 1 || servo motor BSH 100 mm, 3 || servo motor BSH 100 mm, 4 || servo motor BSH 140 mm, 1
Response Time<= 5 ms compliment of STO_A, compliment of STO_B
Signalling Functiondisplay of faults 7 segments
MarkingCE
Net Weight2.6 kg
Contact Bounce Time<= 1 ms compliment of STO_A, compliment of STO_B || 2 µs CAP || 0.25 µs...1.5 ms DI
Connector TypeRJ45 (labelled CN4 or CN5) CANmotion || RJ45 (labelled CN4 or CN5) CANopen || RJ45 (labelled CN7) Modbus
Communication InterfaceCANmotion, Integrated || CANopen, Integrated || Modbus, Integrated
Communication Service1 receive SDO CANmotion || 1 transmit SDO CANmotion || 2 PDOs conforming to DSP 402 CANmotion || 2 SDOs receive CANopen || 2 SDOs send CANopen || 4 configurable mapping PDOs CANopen || CANopen device profile drives and motion control CANopen, CANmotion || display of faults on integrated display terminal Modbus || emergency CANopen, CANmotion || event-triggered, time-triggered, remotely requested,sync (cyclic), sync(acyclic) CANopen || node guarding, heartbeat CANopen || position control mode CANmotion || position control, speed profile, torque profile and homing mode CANopen || sync CANmotion
Braking Current50 mA
Electrical Connectionterminal 3 mm², AWG 12 CN8) || terminal 5 mm², AWG 10 CN1) || terminal 5 mm², AWG 10 CN10)
Type Of Cablesingle-strand IEC cable 50-50 °C) copper 90 °C XLPE/EPR
Discrete Output Voltage<= 30 V DC
Switching Frequency8 kHz
Discrete Output Number2
Discrete Output Logicpositive or negative DO)EN/IEC 61131-2
Discrete Input Typecapture CAP || logic DI || safety compliment of STO_A, compliment of STO_B
Method Of Accessslave
Control Signal Typeservo motor encoder feedback
Safety FunctionSTO (safe torque off), Integrated
Number Of Addresses1-127 CANopen, CANmotion || 1-247 Modbus
Output Voltage<= power supply voltage
Discrete Input Logicpositive compliment of STO_A, compliment of STO_B)< 5 V > 15 V EN/IEC 61131-2 type 1 || positive DI)> 19 V < 9 V EN/IEC 61131-2 type 1 || positive or negative DI)< 5 V > 15 V EN/IEC 61131-2 type 1
Operating Positionvertical +/- 10 degree
Maximum Leakage Current30 mA
Width68 mm
Overvoltage CategoryIII
Depth237 mm
Tightening TorqueCN8 0.5-0.5 N.m || CN1 0.7-0.7 N.m || CN10 0.7-0.7 N.m
Protection Typeagainst reverse polarity inputs signal || against short-circuits outputs signal
Discrete Input Number1 capture || 2 safety || 4 logic
Discrete Output Typelogic DO)24 V DC
Response Time On Output250 µs DO)discrete
Height270 mm
Safety LevelSIL 3 EN/IEC 61508 || PL = e ISO 13849-1
Sampling DurationDI 0.25 ms discrete
Electrical Isolationbetween power and control
Physical Interface2-wire RS485 multidrop Modbus
Status Led1 LED (Red) servo drive voltage || 1 LED error || 1 LED RUN
Discrete Input Voltage24 V DC capture || 24 V DC logic || 24 V DC safety
Transmission Rate1 Mbps 4-4 m CANopen, CANmotion || 125 kbps 500-500 m CANopen, CANmotion || 250 kbps 250-250 m CANopen, CANmotion || 50 kbps 1000-1000 m CANopen, CANmotion || 500 kbps 100-100 m CANopen, CANmotion || 9600, 19200, 38400 bps 40-40 m Modbus

Offer Sustainability

Rohs Exemption InformationYes
Circularity ProfileENVEOLI110605EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Mercury FreeYes
Environmental DisclosureENVPEP110705EN
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationX

Environment

Product CertificationsUL || CSA || TÜV
Type Of Coolingintegrated fan
Ip Degree Of ProtectionIP20 EN/IEC 60529 || IP20 EN/IEC 61800-5-1
Operating Altitude<= 3280.84 ft (1000 m) without derating || > 3280.84...9842.52 ft (> 1000...3000 m) with conditions
Relative HumidityClass 3K3 (5 to 85 %) without condensation IEC 60721-3-3
Ambient Air Temperature For Operation0-50 °C UL
StandardsEN/IEC 61800-3 || EN/IEC 61800-5-1
Shock Resistance15 gn 11 ms EN/IEC 60028-2-27
Environmental Characteristicclasses 3C1 IEC 60721-3-3
Vibration Resistance1 gn 13-150 Hz)EN/IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz)EN/IEC 60068-2-6
Electromagnetic Compatibilityconducted EMC, class A group 1 EN 55011 || conducted EMC, class A group 2 EN 55011 || conducted EMC, environment 2 category C3 EN/IEC 61800-3 || conducted EMC, category C2 EN/IEC 61800-3 || conducted EMC, environments 1 and 2 EN/IEC 61800-3 || electrostatic discharge immunity test, level 3 EN/IEC 61000-4-2 || susceptibility to electromagnetic fields, level 3 EN/IEC 61000-4-3 || 1.2/50 µs shock waves immunity test, level 3 EN/IEC 61000-4-5 || electrical fast transient/burst immunity test, level 4 EN/IEC 61000-4-4 || radiated EMC, class A group 2 EN 55011 || radiated EMC, category C3 EN/IEC 61800-3
Pollution Degree2 EN/IEC 61800-5-1
Ambient Air Temperature For Storage-25-70 °C

Docs


Frequently bought together


Similar items