Modular timing relay, Harmony, 8A, 1CO, 1s..100h, off delay, 24V DC 24...240V AC DC
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 49.19
- Nuova Elva code
- RE17RCMU
- Manufacturer code
- RE17RCMU
- Availability
- Send request for quotation
This Harmony RE17R timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 8A, is 17.5mm wide and can be supplied with 24V DC, 24V to 240V AC. It also has 1 changeover contact SPDT (single pole double throw). It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. This timer offers ON-Delay and OFF-delay Ac, C functions. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0 0
Specifications
Certifications | CSA |
---|---|
Depth | 72 mm |
Height | 90 mm |
Input Voltage | 10 V |
Net Weight | 0.07 kg |
Standard | 2004/108/EC |
Storage Temperature | -30-60 °C |
Width | 17.5 mm |
Specifications | |
Discrete Output Type | relay |
Range Of Product | Harmony Timer Relays |
Product Or Component Type | single function relay |
Time Delay Range | 6...60 s || 1...10 h || 1...10 min || 6...60 min || 0.1...1 s || 1...10 s || 10...100 h |
Nominal Output Current | 8 A |
Width | 17.5 mm |
Time Delay Type | off-delay |
Device Short Name | RE17R |
Complementary | |
Safety Reliability Data | B10d = 270000 || MTTFd = 296.8 years |
Contacts Material | cadmium free |
Power Consumption In Va | 0-32 VA 240 V AC |
Dielectric Strength | 2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1 |
Marking | CE |
Voltage Range | 0.85...1.1 Us |
Reset Time | 120 ms on de-energisation typical |
Operating Rate In Hz | 10 Hz |
Net Weight | 0.07 kg |
Mounting Position | any position in relation to normal vertical mounting plane |
Voltage Drift | +/- 0.2 %/V |
Setting Accuracy Of Time Delay | +/- 10 % of full scale 25 °C IEC 61812-1 |
Maximum Switching Voltage | 250 V AC |
Connections - Terminals | screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end |
Functionality | off-delay timing |
Contacts Type And Composition | 1 C/O |
[Us] Rated Supply Voltage | 24...240 V AC 50/60 Hz || 24 V DC |
Temperature Drift | +/- 0.05 %/°C |
Local Signalling | LED indicator on steady: relay energised, no timing in progress || LED indicator 80 % ON and 20 % OFF flashing: timing in progress || LED indicator 5 % ON and 95 % OFF pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) |
Minimum Switching Current | 10 mA 5 V DC |
Input Voltage | 10 V |
Mounting Support | 35 mm DIN rail conforming to EN/IEC 60715 |
Height | 90 mm |
Electrical Durability | 100000 cycles resistive 8 A 250 V AC |
Mechanical Durability | 10000000 cycles |
Compatibility Code | RE17 |
Breaking Capacity | 2000 VA |
On-Load Factor | 100 % |
Housing Material | self-extinguishing |
Impulse Duration | 100 ms with load in parallel typical || 30 ms typical |
Time Delay Type | C |
[Uimp] Rated Impulse Withstand Voltage | 5 kV 1.2/50 µs |
Depth | 72 mm |
Creepage Distance | 4 kV/3 IEC 60664-1 |
Tightening Torque | 0.6-1 N.m IEC 60947-1 |
Supply Frequency | 50...60 Hz +/- 5 % |
Repeat Accuracy | +/- 0.5 % IEC 61812-1 |
Maximum Delay Response | 100 ms |
Control Type | selector switch front panel |
Insulation Resistance | 100 MOhm 500 V DC IEC 60664-1 |
Maximum Power Consumption In W | 0.6 W 24 V DC |
Maximum Switching Current | 8 A AC/DC |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP121117EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
China Rohs Regulation | X |
Circularity Profile | ENVEOLI121113EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Product Certifications | cULus || GL || CSA |
Relative Humidity | 93-93 % without condensation IEC 60068-2-30 |
Ambient Air Temperature For Operation | -20-60 °C |
Standards | EN 61000-6-4 || EN 61000-6-2 || EN 61000-6-3 || 2004/108/EC || 2006/95/EC || IEC 61812-1 || EN 61000-6-1 |
Immunity To Microbreaks | 20 ms |
Electromagnetic Compatibility | electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2 || electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2 || susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4 || 1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5 || 1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5 || conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6 || voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11 || voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11 || conducted and radiated emissionsclass B EN 55022 |
Shock Resistance | 15 gn 11 ms IEC 60068-2-27 |
Vibration Resistance | 20 m/s² 10-150 Hz)IEC 60068-2-6 |
Ip Degree Of Protection | IP20 IEC 60529 terminal block) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel) |
Ambient Air Temperature For Storage | -30-60 °C |