Safety switch, Telemecanique Safety switches XCS, metal XCSE, 3 NC, slow break, 2 entries tapped Pg 13, 24 V

Manufactured by:
Schneider Electric
Schneider electric

2eeac6d11c5809c30e423d648c80a5389c2f0ad2 medium
Price (VAT excluded)
€ 341.96
Nuova Elva code
XCSE8311
Manufacturer code
XCSE8311
Availability
Send request for quotation

This XCSE Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a robust red coated rectangular Zamak body with 2 x Pg 13.5 cable gland entries, allowing for flexible installation. It has 3 normally closed simultaneous (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 1 normally open and 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.

Specifications

CertificationsCSA
Chain/Cable Diameter9-12 mm
Depth44 mm
Height146-146 mm
MaterialMetal
Net Weight1.14 kg
Number of Poles3
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width98 mm

Specifications

[Us] Rated Supply Voltage24 V - 20...10 %
Designrectangular
Materialmetal
Head Typekey operated turret head
Contacts Type And Composition3 NC
Contact Operationslow-break, simultaneous
Local Signallingfor guard closed and locked 1 LED (green)
Electromagnet Interlockinglocking on de-energisation and unlocking on energisation of solenoid
Cable Outer Diameter9-12 mm
Number Of Poles3
Range Of ProductTelemecanique Safety switches XCS
Cable Entry2 entries tapped Pg 13.5
Electrical Connectionterminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Locking Options Descriptionwith interlocking, locking by solenoid
Solenoid Contacts Type And Composition1 NC + 1 NO slow-break, simultaneous)
Product Or Component Typesafety switch
Signalling Circuit Voltage24/48 V 20...52 V)
Component NameXCSE

Contractual warranty

Warranty18 months

Complementary

Height146-146 mm
Net Weight1.14 kg
[Uimp] Rated Impulse Withstand Voltage6 kV EN/IEC 60947-5-1
Maximum Operating Rate10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage50 VEN/IEC 60947-1 signalling circuit
Positive Openingwith NC contact
Load Factor1
[Ie] Rated Operational Current0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
Minimum Actuator Force For Extraction20 N
Mechanical Durability1000000 cycles
Maximum Actuation Speed0.5 m/s
Short-Circuit Protection10 A cartridge fuse gG (gl)
Body Materialzamak
Safety Reliability DataB10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Width98 mm
Actuator Forcible Withdrawal Rtc2000 N
Depth44 mm
Protection Typeovervoltage protection signalling circuit
Supply Frequency50/60 Hz
Safety Levelcan reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Minimum Actuation Speed0.01 m/s
Signalling Circuit Consumption7 mA
[Ithe] Conventional Enclosed Thermal Current6 A
Power Consumption In Va10 VA inrush || 10 VA sealed
Supply Voltage TypeAC/DC
Head Materialzamak
Signalling Circuit TypeAC/DC

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP110916EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity ProfileENVEOLI110903EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsUL || CSA
Ambient Air Temperature For Operation-25-40 °C
StandardsEN/IEC 60204-1 || EN/IEC 60947-5-1 || CSA C22.2 No 14 || EN/ISO 12100 || UL 508 || EN 1088/ISO 14119
Shock Resistance10 gn 11 ms IEC 60068-2-27
Vibration Resistance5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of ProtectionIP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient Air Temperature For Storage-40-70 °C
Electrical Shock Protection Classclass I EN/IEC 61140
Protective TreatmentTC

Docs


Frequently bought together


Other Schneider Electric items

Request a quote