Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, simple reset by flush push button
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 206.69
- Nuova Elva code
- XY2CE2C250
- Manufacturer code
- XY2CE2C250
- Availability
- Send request for quotation
Specifications
Certifications | CCC |
---|---|
Net Weight | 1.45 kg |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Specifications | |
Housing Colour | red RAL 3000 |
Range Of Product | Telemecanique Emergency stop rope pull switches XY2C |
Overvoltage Category | class I EN/IEC 61140 || class I NF C 20-030 |
Product Or Component Type | latching emergency stop rope pull switch |
Device Short Name | XY2CE |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Trigger Cable Maximum Length | 50 m |
[Ie] Rated Operational Current | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A |
Contact Operation | slow-break |
Distance Between Cable Supports | 5-5 m |
Mechanical Durability | 60000 cycles |
Positive Opening | with EN/IEC 60947-5-1 |
Cable Entry Number | 3 tapped entry Pg 13.5 cable gland |
Compatibility Code | XY2CE |
Body Material | zamak |
[Ithe] Conventional Enclosed Thermal Current | 10 A |
Trigger Cable Anchor Point | LH side |
Connections - Terminals | screw clamp terminal, 1 x 0.5...2 x 1.5 mm² |
Safety Reliability Data | B10d = 300000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5 |
Marking | CE |
Cover Material | stainless steel |
Local Signalling | without pilot light |
Net Weight | 1.45 kg |
Tightening Torque | 0.8-1.2 N.m |
[Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-1 |
Maximum Resistance Across Terminals | 25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A |
Safety Level | can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Reset | by booted push-button |
Contacts Type And Composition | 1 NC + 1 NO |
Number Of Cables | 1 |
Terminals Description Iso N°1 | (13-14)NO || (21-22)NC |
[Ui] Rated Insulation Voltage | 500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14 |
Short-Circuit Protection | 10 A cartridge fuse gG EN/IEC 60269 |
Bellow Material | nitril |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP111159EN |
Sustainable Offer Status | Green Premium product |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Environment | |
Ambient Air Temperature For Operation | -40-70 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Standards | EN/IEC 60947-5-5 || machinery directive 2006/42/EC || EN/IEC 60947-5-1 || EN/ISO 13850 || EN/IEC 60204-1 || CSA C22.2 No 14 || work equipment directive 2009/104/EC || UL 508 |
Product Certifications | UL category NISD emergency stop devices || CSA || CCC |
Shock Resistance | 50 gn 11 ms EN/IEC 60068-2-27 |
Vibration Resistance | 10 gn 10-300 Hz)EN/IEC 60068-2-6 |
Protective Treatment | TC |
Ip Degree Of Protection | IP66 IEC 60529 |