Limit switch body, Limit switches XC Standard, ZCKJ, fixed, w/o display, 1NC+1 NO, snap action, Pg13
- Manufactured by:
- Schneider Electric
This ZCK body/contact assembly with connector has a fixed body and a Zamak body. It has 1 x NO + 1 x NC snap action contacts and a Pg 13.5 cable entry. It can be matched with any head, levers or actuator from the XCKD, XCKP and XCKT ranges.
Specifications
Contact Material | Silver Plated Contacts |
---|---|
Depth | 44 cm |
Height | 81.5-81.5 cm |
Net Weight | 0.34 kg |
Number of Poles | 2 |
Number of Steps | 1 1 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Width | 40 cm |
Specifications | |
Range Of Product | Telemecanique Limit switches XC Standard |
Contact Operation | snap action |
Body Material | metal |
Product Compatibility | XCKJ |
Device Short Name | ZCKJ |
Number Of Poles | 2 |
Contacts Material | silver plated contacts |
Associated Head | ZCKE619 || ZCKE64 || ZCKE629 || ZCKE65 || ZCKE63 || ZCKE67 || ZCKE06 || ZCKE05 || ZCKE21 || ZCKE61 || ZCKE08 || ZCKE23 || ZCKE66 || ZCKE62 |
Cable Entry | 1 entry tapped for Pg 13.5 cable gland |
Product Or Component Type | limit switch body |
Number Of Steps | 1 1 position |
Series Name | standard format |
Contacts Type And Composition | 1 NC + 1 NO |
Body Type | fixed |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Height | 81.5-81.5 cm |
Electrical Durability | 5000000 cycles, DC-13 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C |
[Ui] Rated Insulation Voltage | 500 V 3)IEC 60947-1 contact block || 300 VCSA C22.2 No 14 contact block || 300 VUL 508 contact block |
Positive Opening | with |
[Ie] Rated Operational Current | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A |
Width | 40 cm |
Depth | 44 cm |
Maximum Resistance Across Terminals | 0.25 mOhm IEC 60255-7 category 3 |
Electrical Circuit Type | indicator light module 2 neon lights AC, 110/120 V 95...130 V)20000 h |
Terminals Description Iso N°1 | (11-12)NC || (13-14)NO |
Short-Circuit Protection | 10 A cartridge fuse gG |
Minimum Actuation Speed | 0.01 m/min |
Electrical Connection | screw-clamp terminals 1 x 0.34...2 x 1.5 mm² |
[Ithe] Conventional Enclosed Thermal Current | 10 A |
Local Display | without |
Net Weight | 0.34 kg |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60664 || 6 kV IEC 60947-1 |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP110614EN |
Sustainable Offer Status | Green Premium product |
Toxic Heavy Metal Free | Yes |
Reach Regulation | Free of Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Reach Free Of Svhc | Yes |
China Rohs Regulation | X |
Environment | |
Ambient Air Temperature For Operation | -25-70 °C standard environment |
Ik Degree Of Protection | IK07 |
Ambient Air Temperature For Storage | -40-70 °C |
Environmental Characteristic | standard environment |
Ip Degree Of Protection | IP66 |