Limit switch body, Limit switches XC Standard, ZCKJ, plug in, w/o display, 1C/O, snap action, 1/2"NPT
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 75.78
- Nuova Elva code
- ZCKJ11H7
- Manufacturer code
- ZCKJ11H7
- Availability
- Send request for quotation
The ZCKJ limit switch body is a part of the OsiSense product range of limit switches. It is a metal plug-in body with one closed/open snap action contact. The body has one cable entry tapped for 1/2in NPT conduit and screw clamp terminals for electrical connection. It is a limit switch body with a conventional enclosed thermal current of 10A and rated operating current of 3A at 240V AC and 0.27A at 250V DC. It is furnished with screw terminals for electrical connection. It is an IP66 and IK07 rated product. This plug in limit switch body is made of metal. Its dimensions are 40mm (width) x 44mm (depth) x 77mm (height). It weighs 0.32kg. It is intended for all industrial machine applications such as packaging, materials handling, conveying, machining, food and beverage, service sector, etc. It is compatible with the XCKJ limit switches. The associated heads are ZCKE64, ZCKE62, ZCKE05, ZCKE629, ZCKE66, ZCKE67, ZCKE65, ZCKE21, ZCKE61, ZCKE619 and ZCKE63. Limit switches for contact sensing of inflexible objects. An offer of positive opening snap action contacts for a simpler and safer machine design. IEC standard format limit switches consist of products designed according to EN 50047, EN 50041 as well as popular XCM and XCKM limit switches ranges.
Specifications
Contact Material | Silver Plated Contacts |
---|---|
Depth | 44 mm |
Height | 77-77 mm |
Net Weight | 0.32 kg |
Number of Poles | 1 |
Number of Steps | 1 1 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Width | 40 mm |
Specifications | |
Range Of Product | Telemecanique Limit switches XC Standard |
Contact Operation | snap action |
Body Material | metal |
Product Compatibility | XCKJ |
Device Short Name | ZCKJ |
Number Of Poles | 1 |
Contacts Material | silver plated contacts |
Associated Head | ZCKE64 || ZCKE62 || ZCKE05 || ZCKE629 || ZCKE66 || ZCKE67 || ZCKE65 || ZCKE21 || ZCKE61 || ZCKE08 || ZCKE06 || ZCKE619 || ZCKE63 || ZCKE23 |
Cable Entry | 1 entry tapped for 1/2" NPT conduit |
Product Or Component Type | limit switch body |
Number Of Steps | 1 1 position |
Series Name | standard format |
Contacts Type And Composition | 1 C/O |
Body Type | plug-in body |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Height | 77-77 mm |
Electrical Durability | 5000000 cycles, DC-13 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C |
[Ui] Rated Insulation Voltage | 500 V 3)IEC 60947-1 contact block || 300 VCSA C22.2 No 14 contact block || 300 VUL 508 contact block |
Positive Opening | without |
[Ie] Rated Operational Current | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A |
Width | 40 mm |
Depth | 44 mm |
Maximum Resistance Across Terminals | 0.25 mOhm IEC 60255-7 category 3 |
Electrical Circuit Type | indicator light module 2 LED AC, 110/240 V 95...264 V)100000 h |
Terminals Description Iso N°1 | (21-22)NC || (13-14)NO |
Short-Circuit Protection | 10 A cartridge fuse gG |
Minimum Actuation Speed | 0.01 m/min |
Electrical Connection | screw-clamp terminals 1 x 0.75...2 x 1.5 mm² |
[Ithe] Conventional Enclosed Thermal Current | 10 A |
Local Display | without |
Net Weight | 0.32 kg |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60664 || 6 kV IEC 60947-1 |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP110614EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Ambient Air Temperature For Operation | -25-70 °C standard environment |
Ik Degree Of Protection | IK07 |
Ambient Air Temperature For Storage | -40-70 °C |
Environmental Characteristic | standard environment |
Ip Degree Of Protection | IP66 |