Network cable - NBC-R4AC/2,0-93E/R4AC - 1408934
- Produttore:
- PHOENIX CONTACT
Assembled Ethernet cable, CAT5e, shielded, 2-pair, 26* AWG stranded (7-wire), RAL 5021 (water blue), RJ45 plug/IP20 to RJ45 plug/IP20, line, length: 2 m
Features
EAC
Specifications
Cable Length | 2.00 m |
---|---|
Cable | |
Halogen-free | according to IEC 60754-1 |
Resistance to oil | according to EN 60811-2-1 |
Ambient temperature (operation) | -40 °C - 80 °C (cable, fixed installation) |
Ambient temperature (operation) | -20 °C - 80 °C (cable, flexible installation) |
Ambient temperature (installation) | -20 °C - 80 °C |
Ambient temperature (storage/transport) | -20 °C - 80 °C |
Cable type | Ethernet flexible CAT5, 2-pair |
Cable type (abbreviation) | 93E |
UL AWM style | 20963 (80°C/30 V) |
Signal type/category | Ethernet CAT5 (IEC 11801), 100 Mbps |
Cable structure | 2x2xAWG26/7; SF/UTP |
Conductor cross section | 2x 2x 0.14 mm² |
AWG signal line | 26 |
Conductor structure signal line | 7x 0.16 mm |
Core diameter including insulation | 0.98 mm |
Wire colors | white/orange-orange, white/green-green |
Twisted pairs | 2 cores to the pair |
Overall twist | Two pairs with two fillers to the core |
Shielding | Aluminum-coated foil, tinned copper braided shield |
Optical shield covering | 70 % |
External sheath, color | water blue RAL 5021 |
Outer sheath thickness | 1.2 mm |
External cable diameter D | 6.4 mm ±0.2 mm |
Minimum bending radius, fixed installation | 4 x D |
Minimum bending radius, flexible installation | 8 x D |
Tensile strength GRP | ≤ 80 N |
Cable weight | 42 kg/km |
Outer sheath, material | PUR |
Material conductor insulation | Foamed PE |
Conductor material | Bare Cu litz wires |
Standards/specifications | Electrical requirements EN 50288-2-2 |
Insulation resistance | ≥ 500 MΩ*km |
Loop resistance | ≤ 290.00 Ω/km |
Cable capacity | approx. 45 nF/km (at 1 kHz) |
Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
Near end crosstalk attenuation (NEXT) | 65.3 dB (with 1 MHz) |
Near end crosstalk attenuation (NEXT) | 56.3 dB (at 4 МHz) |
Near end crosstalk attenuation (NEXT) | 50.3 dB (at 10 MHz) |
Near end crosstalk attenuation (NEXT) | 47.2 dB (at 16 MHz) |
Near end crosstalk attenuation (NEXT) | 45.8 dB (at 20 МHz) |
Near end crosstalk attenuation (NEXT) | 42.9 dB (at 31.25 МHz) |
Near end crosstalk attenuation (NEXT) | 38.4 dB (at 62.5 МHz) |
Near end crosstalk attenuation (NEXT) | 35.3 dB (at 100 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 62.3 dB (with 1 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 53.3 dB (at 4 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 47.3 dB (at 10 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 44.2 dB (at 16 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 42.8 dB (at 20 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 39.9 dB (at 31.25 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 35.4 dB (at 62.5 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 32.3 dB (at 100 MHz) |
Attenuation | 3.2 dB (with 1 MHz) |
Attenuation | 6 dB (at 4 МHz) |
Attenuation | 9.5 dB (at 10 MHz) |
Attenuation | 12.1 dB (at 16 MHz) |
Attenuation | 13.6 dB (at 20 МHz) |
Attenuation | 17.1 dB (at 31.25 МHz) |
Attenuation | 24.8 dB (at 62.5 МHz) |
Attenuation | 32 dB (at 100 MHz) |
Return loss (RL) | 23 dB (at 4 МHz) |
Return loss (RL) | 24.1 dB (at 8 МHz) |
Return loss (RL) | 25 dB (at 10 MHz) |
Return loss (RL) | 25 dB (at 16 MHz) |
Return loss (RL) | 25 dB (at 20 МHz) |
Return loss (RL) | 23.6 dB (at 31.25 МHz) |
Return loss (RL) | 21.5 dB (at 62.5 МHz) |
Return loss (RL) | 20.1 dB (at 100 MHz) |
Signal runtime | 5.3 ns/m |
Coupling resistance | ≤ 100.00 mΩ/m (at 10 MHz) |
Nominal voltage, cable | ≤ 100 V (Peak value, not for high-power applications) |
Test voltage Core/Core | 700 V (50 Hz, 1 min.) |
Test voltage Core/Shield | 700 V (50 Hz, 1 min.) |
Current carrying capacity of cable | 2 A (according to DIN VDE 0891-1) |
Flame resistance | according to IEC 60332-1-2 |
Flame resistance | in acc. to UL VW1 |
General data | |
Number of slots | 1 |
Rated current at 40°C | 1 A |
Rated voltage | 48 V |
Number of positions | 4 |
Alternative short product description | Ethernet cable |
Rated voltage (III/3) | 72 V (DC) |
Degree of protection | IP20 |
Dimensions | |
Length of cable | 2.00 m |
Characteristics head 1 | |
Color | gray |
Material (component) | CuSn (Contact) |
Material (component) | Ni/Au (Contact surface) |
Material (component) | PC (Contact carriers) |
Material (component) | PA (Housing) |
Insertion/withdrawal cycles | ≥ 750 |
Ambient temperature (operation) | -40 °C - 60 °C |
Shielded | yes |
Outer sheath, material | PUR |
External sheath, color | water blue RAL 5021 |
Type type, plug side | Plug straight |
Type type, socket side | Plug, straight |
Characteristics head 2 | |
Color | gray |
Material (component) | CuSn (Contact) |
Material (component) | Ni/Au (Contact surface) |
Material (component) | PC (Contact carriers) |
Material (component) | PA (Housing) |
Insertion/withdrawal cycles | ≥ 750 |
Ambient temperature (operation) | -40 °C - 60 °C |
Ambient conditions | |
Degree of protection | IP20 (RJ45 connector) |
Ambient temperature (operation) | -20 °C - 70 °C (RJ45 connector) |
Standards and Regulations | |
Flammability rating according to UL 94 | V2 |
Environmental Product Compliance | |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
China RoHS | No hazardous substances above threshold values |