Uninterruptible power supply - QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - 2320254
- Produttore:
- PHOENIX CONTACT
Uninterruptible energy supply with IQ technology and integrated energy storage for DIN rail mounting, input 24 V DC, output: 24 V DC/5 A, energy storage: lead AGM 1.3 Ah, incl. mounted UTA 107/30 universal DIN rail adapter
Features
Easy handling thanks to automatic battery detection, tool-free battery replacement during operation, and communication via the IFS interface
Reliable starting of difficult loads with the static POWER BOOST power reserve with up to 1.5 times the nominal current permanently
Fast tripping of standard circuit breakers with SFB (selective fuse breaking) technology
Device suitable for universal use thanks to comprehensive license package and extensive parameterization and diagnostics options
cULus Listed
EAC
cULus Recognized
UL Listed
cUL Listed
UL Recognized
cUL Recognized
Specifications
Depth | 125 mm |
---|---|
Height | 138 mm |
Output Voltage | 24 V |
Strip Length | 7 mm |
Voltage | 10 V |
Width | 88 mm |
Output data (24 V DC battery operation) | |
Nominal output voltage | 24 V DC |
Output voltage range (depends on the input voltage) | 19.2 V DC - 27.6 V DC (UOUT = UBAT - 0.5 V DC) |
Nominal output current (IN) | 5 A (0 °C - 40 °C) |
POWER BOOST (IBoost) | 7.5 A (0 °C - 40 °C) |
Selective Fuse Breaking (ISFB) | 32.5 A (0 °C - 40 °C) |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 3 |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Output data (24 V DC mains operation) | |
Nominal output voltage | 24 V DC |
Output voltage range (depends on the input voltage) | 18 V DC - 30 V DC (UOUT = UIN - 0.1 V DC) |
Nominal output current (IN) | 5 A (0 °C - 40 °C) |
POWER BOOST (IBoost) | 7.5 A (0 °C - 40 °C) |
Selective Fuse Breaking (ISFB) | 30 A (0 °C - 40 °C) |
Standards | |
EMC requirements for noise immunity | EN 61000-6-1 |
EMC requirements for noise immunity | EN 61000-6-2 |
EMC requirements for noise emission | EN 61000-6-3 |
EMC requirements for noise emission | EN 61000-6-4 |
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Rail applications | EN 50121-4 |
Dimensions | |
Width | 88 mm |
Height | 138 mm |
Depth | 125 mm |
Installation distance right/left | 5 mm / 5 mm |
Installation distance top/bottom | 50 mm / 50 mm |
EMC data | |
I/O/S | asymmetrical |
Frequency range | 0.15 MHz - 80 MHz |
Voltage | 10 V (Test Level 3) |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Electrostatic discharge | EN 61000-4-2 |
Contact discharge | 8 kV (Test Level 4) |
Discharge in air | 15 kV (Test Level 4) |
Electromagnetic HF field | EN 61000-4-3 |
Frequency range | 80 MHz - 1 GHz |
Test field strength | 20 V/m |
Frequency range | 1 GHz - 2 GHz |
Test field strength | 10 V/m |
Frequency range | 2 GHz - 3 GHz |
Test field strength | 3 V/m |
Comments | Criterion A |
Fast transients (burst) | EN 61000-4-4 |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 2 kV (Test Level 4 - asymmetrical) |
Surge voltage load (surge) | EN 61000-4-5 |
Input | 1 kV (Test Level 2 - symmetrical) |
Output | 1 kV (Test Level 2 - symmetrical) |
Signal | 1 kV (Test Level 2 - asymmetrical) |
Input data | |
Input voltage | 24 V DC |
Input voltage range | 18 V DC - 30 V DC |
Current consumption (maximum) | 9.3 A (24 V DC) |
Current consumption (idle) | 9.7 mA |
Current consumption (charging process) | 1.7 A |
Fixed backup threshold | ≤ 22.6 V DC |
Energy storage | |
Battery technology | VRLA |
Accumulator type | 2x Panasonic LC-R121R3PG |
Buffer period | 50 min. (1 A) |
Buffer period | 5 min. (5 A) |
Connection data, input | |
Connection method | Pluggable screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 20 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M4 |
Connection data, output | |
Connection method | Pluggable screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 20 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M4 |
Ambient conditions | |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Degree of protection | IP20 |
Ambient temperature (operation) | 0 °C - 40 °C |
Ambient temperature (storage/transport) | -15 °C - 40 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (25 °C, non-condensing) |
Connection data for signaling | |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Screw thread | M4 |
Conformance/approvals | |
UL approvals | UL/C-UL Recognized UL 60950-1 |
UL approvals | UL Listed UL 508 |
General output data | |
Efficiency | > 97.1 % (Mains operation, with charged energy storage) |