I/O module - AXL F AI4 I 1H - 2688491
- Produttore:
- PHOENIX CONTACT
Axioline F, Analog input module, Analog inputs: 4, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2, 3, 4-wire, transmission speed in the local bus: 100 Mbps, integrated sensor supply, degree of protection: IP20, including bus base module and Axioline F connectors
Features
4 analog, bipolar input channels for the connection of current signals
Connection of sensors in 2, 3, and 4-wire technology
Current ranges: 0 mA ... 20 mA, 4 mA ... 20 mA, ±20 mA
Simultaneous scanning of all channels by means of simultaneous sampling
High crosstalk attenuation between the channels, thanks to separate signal paths
Particularly robust against electromagnetic interference
Device rating plate stored
BV
BSH
cULus Listed
EAC
LR
RINA
PRS
DNV GL
KR
ABS
UL Listed
cUL Listed
Specifications
Depth | 54 mm |
---|---|
Height | 126.1 mm |
Strip Length | 8 mm |
Width | 35 mm |
Electrical isolation | |
Test section | 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min. |
Test section | 5 V supply (logic)/analog inputs 500 V AC 50 Hz 1 min. |
Test section | 5 V supply of the local bus (UBus) / functional ground 500 V AC 50 Hz 1 min. |
Test section | 24 V supply (I/O)/analog inputs 500 V AC 50 Hz 1 min. |
Test section | 24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min. |
Test section | Analog inputs/functional earth ground 500 V AC 50 Hz 1 min. |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Connection data | |
Designation | Axioline F connector |
Connection method | Push-in connection |
Note on the connection method | Please observe the information provided on conductor cross sections in the 'Axioline F: system and installation' user manual. |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Axioline potentials | |
Designation | Axioline F local bus supply (UBus) |
Supply voltage | 5 V DC (via bus base module) |
Current consumption | typ. 120 mA |
Current consumption | max. 150 mA |
Designation | Supply for analog modules (UA) |
Supply voltage | 24 V DC (I/O supply and sensor supply) |
Supply voltage range | 19.2 V DC - 30 V DC (including all tolerances, including ripple) |
Current consumption | max. 45 mA (IiS = 0 mA) |
Current consumption | typ. 118 mA (IiS = 4 x 20 mA (nominal load)) |
Current consumption | max. 125 mA (IiS = 4 x 20 mA (nominal load)) |
Current consumption | typ. 238 mA (IiS = 4 x 50 mA (full load)) |
Current consumption | max. 245 mA (IiS = 4 x 50 mA (full load)) |
Power consumption | typ. 1.5 W (at UBus and UA) |
Power consumption | max. 1.83 W (at UBus and UA) |
Protective circuit | Surge protection of the supply voltage electronic (35 V, 0.5 s) |
Protective circuit | Polarity reversal protection of the supply voltage up to HW 02: polarity protection diodeas of HW 03: parallel diode; with external 5 A fuse (for startup only) |
Protective circuit | Transient protection supply voltage Suppressor diode |
Dimensions | |
Width | 35 mm |
Height | 126.1 mm |
Depth | 54 mm |
Note on dimensions | The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). |
Interfaces | |
Designation | Axioline F local bus |
No. of channels | 2 |
Connection method | Bus base module |
Transmission speed | 100 Mbps |
Analog inputs | |
Description of the input | Differential inputs, current |
Input name | Analog inputs |
Number of inputs | 4 |
Connection method | Push-in connection |
Connection technology | 2, 3, 4-wire |
Note regarding the connection technology | shielded |
A/D conversion time | 31.25 µs |
A/D converter resolution | 16 bit |
Limit frequency (3 dB) | 30 Hz |
Limit frequency (3 dB) | 12 kHz |
Type of protection | Transient protection of inputs |
Type of protection | Overload protection of the inputs |
Data formats | IB IL, S7-compatible |
Measured value representation | 16 bits (15 bits + sign bit) |
Current input signal | 0 mA - 20 mA |
Current input signal | 4 mA - 20 mA |
Current input signal | -20 mA - 20 mA |
Input resistance current input | 104 Ω (typical) |
Input filter | 30 Hz, 12 kHz and mean-value generation (can be parameterized) |
Ambient conditions | |
Air pressure (operation) | 70 kPa - 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa - 106 kPa (up to 3000 m above sea level) |
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C - 60 °C |
Ambient temperature (storage/transport) | -40 °C - 85 °C |
Permissible humidity (operation) | 5 % - 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % - 95 % (non-condensing) |
Standards and Regulations | |
Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
Mechanical tests | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g |
Mechanical tests | Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |