Controller - ILC 131 ETH - 2700973
- Produttore:
- PHOENIX CONTACT
The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3).
Features
PROFINET-Device
Modbus/TCP-Client
Numerous protocols supported such as: http, https, FTP, SNTP, SNMP, SMTP, SQL, MySQL, DCP, etc.
Free engineering with PC Worx Express (IEC 61131-3)
Program memory and mass storage (192 kB/192 kB)
Modbus/TCP server
HTML 5
Integrated web server for visualization with WebVisit/atvise®
Complete INTERBUS master (2048 I/O points)
SD card up to 2 GB as optional plug-in parameterization memory
BV
BSH
cULus Listed
ATEX
EAC
LR
RINA
DNV GL
ABS
UL Listed
cUL Listed
Specifications
Depth | 71.5 mm |
---|---|
Height | 119.8 mm |
Width | 80 mm |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Standards and Regulations | |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Interference emission | Noise emission test as per EN 61000-6-4 EN 55011 Class A |
Immunity to surge | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV |
Immunity to burst | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV |
Immunity to EF | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
Immunity to ESD | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge |
Immunity to conducted interference | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V |
Vibration (storage/transport) | 5g |
Shock | 25g, Criterion 1, according to IEC 60068-2-27 |
Vibration (operation) | 5g |
Dimensions | |
Width | 80 mm |
Height | 119.8 mm |
Depth | 71.5 mm |
Data interfaces | |
Interface | Ethernet 10Base-T/100Base-TX |
Number | 1 |
Connection method | RJ45 jack |
Transmission speed | 10/100 Mbps |
Interface | INTERBUS local bus (master) |
Connection method | Inline data jumper |
Transmission speed | 500 kBaud / 2 MBaud (can be switched) |
Interface | Parameterization/operation/diagnostics |
Connection method | 6-pos. MINI DIN socket (PS/2) |
Transmission speed | max. 115.2 kbps |
Direct I/Os | |
Input name | Digital inputs |
Number of inputs | 8 |
Connection method | Inline potential distributor |
Connection technology | 2, 3, 4-wire |
Description of the input | EN 61131-2 type 1 NPN/PNP |
Output name | Digital outputs |
Number of outputs | 4 |
Connection method | Spring-cage connection |
Maximum output current per channel | 500 mA |
Mechanical design | |
Weight | 285 g |
Diagnostics display | No |
Controller redundancy | No |
Safety function | No |
Control system | |
Engineering tool | PC WORX |
Engineering tool | PC WORX EXPRESS |
Programming languages supported | Programming in acc. with IEC 61131-3 |
Diagnostics tool | DIAG+ |
Configuration tool | Config+ Version 1.01 or later |
Power supply | |
Typical current consumption | 210 mA |
Max. current consumption | 870 mA (370 mA communications power + 500 mA analog voltage supply) |
Supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC - 30 V DC |
Residual ripple | ± 5 % |
Power dissipation | max. 5 W |
PROFINET | |
Device function | PROFINET device |
Fieldbus function | |
Amount of process data | max. 4096 Bit (INTERBUS) |
Amount of process data | max. 8192 Bit (internal Modbus /TCP client) |
Number of supported devices | max. 63 |
Number of local bus devices that can be connected | max. 63 (observe current consumption) |
Number of devices with parameter channel | max. 8 |
Program memory | 192 kByte |
General data | |
Processor | Altera Nios II 64 MHz |
Ambient conditions | |
Air pressure (operation) | 70 kPa - 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa - 106 kPa (up to 3000 m above sea level) |
Shock | 25g, Criterion 1, according to IEC 60068-2-27 |
Vibration (operation) | 5g |
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C - 55 °C |
Ambient temperature (storage/transport) | -25 °C - 85 °C |
Permissible humidity (operation) | 10 % - 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport) | 10 % - 95 % (according to DIN EN 61131-2) |
IEC 61131 runtime system | |
Engineering tool | PC WORX |
Engineering tool | PC WORX EXPRESS |
Program memory | 192 kByte |
Mass storage | 192 kByte |
Retentive mass storage | 8 kByte (NVRAM) |
Number of control tasks | 8 |
Realtime clock | Yes |
Note | |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |