Bus coupler - AXL F BK PN - 2701815
- Produttore:
- PHOENIX CONTACT
Axioline F bus coupler for PROFINET (including bus base module and connector)
Features
Up to 63 additional Axioline devices can be connected
PROFIsafe support
2 RJ45 connections
BootP and DCP
Diagnostic and status indicators
Firmware can be updated
Typical cycle time of the Axioline F local bus is around 10 μs
Safe analog value processing with SAFE AI and other components
BV
PROFINET
EAC
LR
RINA
PRS
NK
DNV GL
KR
ABS
UL Listed
cUL Listed
Specifications
Depth | 74 mm |
---|---|
Height | 126.1 mm |
Strip Length | 8 mm |
Width | 45 mm |
Axioline potentials | |
Designation | Communications power UL feed-in (the supply of the Axioline F local bus UBus is generated from UL) |
Supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC - 30 V DC (including all tolerances, including ripple) |
Current consumption | max. 570 mA (with 2 A at UBus for the I/Os and UL = 24 V) |
Power consumption | max. 13.7 W (with 2 A load at UBus for the I/Os) |
Designation | Axioline F local bus supply (UBus) |
Supply voltage | 5 V DC (via bus base module) |
Power supply unit | 2 A |
Protective circuit | Surge protection of the supply voltage electronic |
Protective circuit | Polarity reversal protection of the supply voltage electronic |
Ambient conditions | |
Permissible humidity (storage/transport) | 5 % - 95 % (non-condensing) |
Air pressure (operation) | 70 kPa - 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa - 106 kPa (up to 3000 m above sea level) |
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C - 60 °C (Mounting position: wall mounting on horizontal DIN rail) |
Ambient temperature (operation) | -25 °C - 55 °C (Mounting position: any) |
Ambient temperature (storage/transport) | -40 °C - 85 °C |
Permissible humidity (operation) | 5 % - 95 % (non-condensing) |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Connection data | |
Designation | Axioline F connector |
Connection method | Push-in connection |
Note on the connection method | Please observe the information provided on conductor cross sections in the 'Axioline F: system and installation' user manual. |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Dimensions | |
Width | 45 mm |
Height | 126.1 mm |
Depth | 74 mm |
Note on dimensions | The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). |
Interfaces | |
Designation | PROFINET |
No. of channels | 2 |
Connection method | RJ45 jack |
Note on the connection method | Auto negotiation and autocrossing |
Transmission speed | 100 Mbps (full duplex) |
Transmission physics | Ethernet in RJ45 twisted pair |
Designation | Axioline F local bus |
Connection method | Bus base module |
Transmission speed | 100 Mbps |
Designation | Service |
Connection method | Micro USB type B |
Inline potentials | |
Supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC - 30 V DC (including all tolerances, including ripple) |
Digital inputs | |
Connection technology | Push-in connection |
System limits of the bus coupler | |
Amount of process data | max. 524 Byte (Max. 262 bytes IN - max. 262 bytes OUT) |
Amount of process data | max. 262 Byte (Input) |
Amount of process data | max. 262 Byte (Output) |
Number of supported devices | max. 63 (per station) |
Number of local bus devices that can be connected | max. 63 |
Standards and Regulations | |
Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
Mechanical tests | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g |
Mechanical tests | Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |