Surge protection device - CN-LAMBDA/4-2.25-BB - 2801057
- Produttore:
- PHOENIX CONTACT
Attachment plug with Lambda/4 technology as surge protection for coaxial signal interfaces. Connection: N connectors socket-socket
Features
EAC
Specifications
Height | 77.5 mm |
---|---|
Length | 78.7 mm |
Width | 25 mm |
Dimensions | |
Height | 77.5 mm |
Width | 25 mm |
Length | 78.7 mm |
Ambient conditions | |
Ambient temperature (operation) | -40 °C - 85 °C |
Altitude | 2000 m |
Degree of protection | IP68 |
Protective circuit | |
IEC test classification | C2 |
IEC test classification | C3 |
IEC test classification | D1 |
Nominal current IN | 5 A (25 °C) |
Nominal discharge current In (8/20) µs | 50 kA |
Nominal discharge current In (8/20) µs (line-earth) | 50 kA |
Nominal discharge current In (8/20) µs (line-shield) | 50 kA |
Total surge current (8/20) µs | 60 kA |
Total surge current (10/350) µs | 20 kA |
Max. discharge current Imax (8/20) µs | 60 kA |
Max. discharge current Imax (8/20) µs maximum (line-earth) | 60 kA |
Max. discharge current Imax (8/20) µs maximum (line-shield) | 60 kA |
Impulse discharge current (10/350) µs, peak value limp | 20 kA |
Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 1 V |
Output voltage limitation at 1 kV/µs (line-shield) spike | ≤ 1 V |
Voltage protection level Up (line-earth) | ≤ 25 V (C2 - 10 kV / 5 kA) |
Voltage protection level Up (line-earth) | ≤ 5 V (C1 - 1 kV/500 A) |
Voltage protection level Up (line-earth) | ≤ 18 V (6 kV / 3 kA) |
Voltage protection level Up (line-shield) | ≤ 5 V (C1 - 1 kV/500 A) |
Voltage protection level Up (line-shield) | ≤ 25 V (C2 - 10 kV / 5 kA) |
Voltage protection level Up (line-shield) | ≤ 18 V (6 kV / 3 kA) |
Input attenuation aE, asym. | typ. 0.1 dB |
Frequency range | 0.8 GHz - 2.25 GHz |
Standing wave ratio SWR in a 50 Ω system | typ. 1.2 |
Standing wave ratio SWR in a 50 Ω system | max. 1.25 |
Permissible HF power Pmax at VSWR = xx (50 ohm system) | ≤ 500 W |
Permissible HF power Pmax at VSWR = xx (50 ohm system) | ≤ 4 kW (peak) |
Surge protection fault message | none |
Impulse durability (line-earth) | C1 - 1 kV / 500 A |
Impulse durability (line-earth) | C2 - 10 kV / 5 kA |
Impulse durability (line-earth) | D1 - 2.5 kA |
Connection data | |
Connection method | N connector 50 Ω |
Connection method IN | N connector, female |
Connection method OUT | N connector, female |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
Standards and Regulations | |
Standards/specifications | IEC 61643-21/A1 2008 |
Standards/specifications | EN 61643-21/A1 2009 |