I/O module - ILB PB 24 DI16 DO16 - 2862411

Produttore:
PHOENIX CONTACT
Phoenix%20contact

5b07262344f5b719e0ceb651bf099f9b731fc32d medium
Prezzo (IVA esclusa)
€ 264.59
Codice Nuova Elva
2862411
Codice produttore
2862411
Disponibilità
Invia RdO

Inline, Block IO, PROFIBUS DP, D-SUB-9 female connector, Digital inputs: 16, 24 V DC, connection method: 3-wire, Digital outputs: 16, 24 V DC, 500 mA, connection method: 3-wire, degree of protection: IP20, including Inline connector

Features

  • 16 digital inputs

  • 16 digital outputs

  • Connection of sensors in 2 and 3-wire technology

  • Connection of actuators in 2 and 3-wire technology

  • Maximum permissible load current per sensor: 125 mA

  • Nominal current per output: 500 mA

  • Diagnostic and status indicators

  • cULus Listed

  • PROFIBUS

  • cULus Recognized

  • UL Listed

  • cUL Listed

  • UL Recognized

  • cUL Recognized

Specifications

Depth57 mm
Height141 mm
Output Voltage24 V
Width156 mm

Dimensions

CaptionThe figure shows the general dimensional drawing of the Inline Block IO product family
Width156 mm
Height141 mm
Depth57 mm
Note on dimensionsSpecfications with connectors

Interfaces

DesignationPROFIBUS DP
Connection methodD-SUB-9 female connector
Transmission speed9.6 kbps - 12 Mbps
Number of positions9

Digital inputs

Input nameDigital inputs
Description of the inputEN 61131-2 type 1
Connection methodSpring-cage connection
Connection technology3-wire
Number of inputs16
Typical response timeapprox. 500 µs
Protective circuitShort-circuit protection, overload protection of the sensor supply
Nominal input voltage UIN24 V DC
Nominal input current at UIN5 mA
Input voltage24 V DC
Input voltage range "0" signal-30 V DC - 5 V DC
Input voltage range "1" signal15 V DC - 30 V DC

Digital outputs

Output nameDigital outputs
Connection methodSpring-cage connection
Connection technology3-wire
Number of outputs16
Protective circuitShort-circuit and overload protection
Output voltage24 V DC
Nominal output voltage24 V DC
Maximum output current per channel500 mA
Maximum output current per module / terminal block8 A
Maximum output current per module8 A
Nominal load, inductive12 VA
Nominal load, lamp12 W
Nominal load, ohmic12 W
Limitation of the voltage induced on circuit interruptionapprox. -36 V

Ambient conditions

Permissible humidity (operation)85 % (non-condensing)
Permissible humidity (storage/transport)95 % (non-condensing)
Air pressure (operation)80 kPa - 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)66 kPa - 108 kPa (up to 3500 m above sea level)
Degree of protectionIP20
Ambient temperature (operation)-25 °C - 60 °C
Ambient temperature (storage/transport)-25 °C - 85 °C

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
China RoHSNo hazardous substances above threshold values

Standards and Regulations

Noise emissionIndustrial environment
Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Mechanical testsShock in acc. with EN 60068-2-27/IEC 60068-2-27 25g
Connection in acc. with standardCUL

Electrical isolation

Test sectionI/Os / PROFIBUS 500 V AC 50 Hz 1 min.
Test sectionI/O area / FE 500 V AC 50 Hz 1 min.
Test sectionPROFIBUS / FE 500 V AC 50 Hz 1 min.

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Spesso acquistati assieme


Altri articoli da PHOENIX CONTACT

Richiedi un preventivo