Modular 3 phase supply control relay, Harmony, 5A, 2CO, 208...440V AC

Produttore:
Schneider Electric
Schneider electric

Ba0d79d31ff7b3f9f57a2b02d89cea37cee79adb medium
Prezzo (IVA esclusa)
€ 76.03
Codice Nuova Elva
RM17TG20
Codice produttore
RM17TG20
Disponibilità
Invia RdO

This Harmony RM17-TG relay allows monitoring of power supply circuits in 3-phase networks. This modular multi function 3-phase supply control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with screw trimmers. The product monitors its own power supply, when the power supply is abnormal, the output relay de-energizes. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0

Specifications

CertificationsC-tick
Housing MaterialPlastic
Net Weight0.13 kg
Operating Cycles360
StandardEN/IEC 60255-1
Storage Temperature-40-70 °C
Warranty Length18 months
Width17.5 mm

Specifications

Range Of ProductHarmony Control Relays
Relay Monitored Parametersphase sequence || phase failure detection (2 or more phase cut)
[Uc] Control Circuit Voltage208...440 V
Measurement Range208...440 V voltage AC
Switching Capacity In Va1250 VA
Product Or Component Type3-phase control relay
Relay NameRM17TG
Contacts Type And Composition2 C/O
Relay Typecontrol relay
Product Specific Applicationfor 3-phase supply
Time Delay Typewithout

Contractual warranty

Warranty18 months

Complementary

Voltage Range183...484 V
MarkingCE
Response Time<= 130 ms (in the event of a fault)
Operating Positionany position without derating
Utilisation CategoryAC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1
Net Weight0.13 kg
Maximum Switching Voltage250 V AC || 250 V DC
Measurement Voltage Limits183-484 V AC
Connections - Terminalsscrew terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
[Ui] Rated Insulation Voltage400 V IEC 60664-1
Overvoltage CategoryIII IEC 60664-1
Safety Reliability DataB10d = 850000 || MTTFd = 924.6 years
Supply Voltage Limits183-484 V AC
Mounting Support35 mm symmetrical DIN rail conforming to EN/IEC 60715
Nominal Output Current5 A
Local Signallingfor relay ON LED (yellow)
Mechanical Durability30000000 cycles
Housing Materialself-extinguishing plastic
Control Circuit Frequency50...60 Hz +/- 10 %
Width17.5 mm
Tightening Torque0.6-1 N.m IEC 60947-1
Electrical Durability10000 cycles
Minimum Switching Current10 mA 5 V DC
Run-Up Delay At Power-Up650 ms
Supply Frequency50/60 Hz +/- 10 %
Control Circuit Voltage Limits12 % + 10 % Un
Insulation Resistance> 500 MOhm 500 V DC IEC 60255-5 || > 500 MOhm 500 V DC IEC 60664-1
Operating Rate<= 360 operations/hour full load
Power Consumption In Va0-22 VA 400 V AC 50 Hz
Output Contacts2 C/O
Voltage Detection Threshold< 100 V AC

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP1504008EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs RegulationX
Circularity ProfileENVEOLI1504008EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsGOST || C-tick || UL || CSA || GL
Pollution Degree3 IEC 60664-1
Directives73/23/EEC - low voltage directive || 89/336/EEC - electromagnetic compatibility
Ambient Air Temperature For Storage-40-70 °C
Relative Humidity95-95 % 55-55 °C IEC 60068-2-30
StandardsEN/IEC 60255-1
Non-Dissipating Shock Wave4 kV
Dielectric Test Voltage2 kV AC 50 Hz, 1 min
Electromagnetic Compatibilityemission standard for industrial environments EN/IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || immunity for industrial environments EN/IEC 61000-6-2
Shock Resistance15 gn 11 ms IEC 60255-21-1
Ambient Air Temperature For Operation-20-50 °C
Vibration Resistance0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1
Ip Degree Of ProtectionIP20 IEC 60529 terminals) || IP30 IEC 60529 casing)