module XPSOT - stop at top dead center with automatic overtravel - 115 V AC

Produttore:
Schneider Electric
Schneider electric

80c48bdbe92afc295f66b65b85659d16d8224d93 medium
Prezzo (IVA esclusa)
€ 1187.87
Codice Nuova Elva
XPSOT3444
Codice produttore
XPSOT3444
Disponibilità
Invia RdO

Specifications

CertificationsCSA
Depth118 mm
Enclosure MaterialPolycarbonate
Height73 mm
Net Weight1.1 kg
StandardEN 60204-1
Storage Temperature-25-85 °C
Warranty Length18 months
Width200 mm

Specifications

Number Of Additional Circuits4 solid state outputs
Safety Module NameXPSOT
Safety Levelcan reach PL e/category 4 EN/ISO 13849-1 || can reach SILCL 3 EN/IEC 62061
Output Typerelay, 3 NO, volt-free
[Us] Rated Supply Voltage115 V AC - 15...15 %
Range Of ProductPreventa Safety automation
Safety Module Applicationsafety stop with automatic overtravel monitoring and control
Safety Reliability DataMTTFd = 60.9 years EN/ISO 13849-1 || DC = 0...99 % EN/ISO 13849-1 || PFHd = 1.33E-8 1/h EN/IEC 62061
Product Or Component TypePreventa safety module
Function Of Modulesafety stop with automatic overtravel monitoring and control
Enclosure Typeremovable

Contractual warranty

Warranty18 months

Complementary

Connections - Terminalscaptive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² with cable end || captive screw clamp terminals, 2 x 2.5 mm² without cable end
Enclosure Materialpolycarbonate
Minimum Output Current10 mA relay output
Width200 mm
[Ith] Conventional Free Air Thermal Current2.5 A
Depth118 mm
Associated Fuse Rating4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
[Uimp] Rated Impulse Withstand Voltage4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
Net Weight1.1 kg
Breaking Capacity10 mA 48 V solid state output circuit || 20 mA 24 V solid state output circuit || 1.5 A 24 V DC-13)50 ms relay output
Supply Frequency50/60 Hz
Height73 mm
Maximum Response Time On Input Open20 ms
Breaking Capacity180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output
[Ui] Rated Insulation Voltage300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
Power Consumption In Va12 VA
Mounting Support35 mm symmetrical DIN rail
Local Signalling4 LEDs
Number Of Terminal Blocks42
Minimum Output Voltage17 V relay output
Input Protection Typeinternal, electronic

Offer Sustainability

China Rohs RegulationX
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of SvhcYes
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Circularity ProfileENVEOLI1408008EN
Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP1408008EN
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Reach RegulationFree of Substances of Very High Concern above the threshold

Environment

Product CertificationsCSA || UL || TÜV
Ambient Air Temperature For Operation-10-55 °C
Ambient Air Temperature For Storage-25-85 °C
StandardsEN 692 || EN/IEC 60947-5-1 || EN 60204-1
Ip Degree Of ProtectionIP10 terminals)EN/IEC 60529 || IP40 enclosure)EN/IEC 60529

Documentazione


Spesso acquistati assieme


Articoli correlati


Richiedi un preventivo