Safety module, Harmony Safety Automation, Cat.4, potential free NC/NC, NO/NC, PNP/PNP, 24v AC/DC, screw

Produttore:
Schneider Electric
Schneider electric

828e9a6009cff811a5aef757d39558df7b292869 medium
Prezzo (IVA esclusa)
€ 170.07
Codice Nuova Elva
XPSUAF13AP
Codice produttore
XPSUAF13AP
Disponibilità
1 in stock
Ricerche correlate

Modulo Sicurezza Safety Module


This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch or Safety light curtain. The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 safety inputs, 3 ON/OFF configurable pulsed outputs, 3 NO safety outputs, and 1 solid state diagnostic output with complete status information. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILC L 3 conforming to IEC 62061, and SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÜV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.

Specifications

CertificationsCULus
Contact Configuration3 NO
Depth120 mm
Height100 mm
Net Weight0.200 kg
Number of Outputs3
StandardIEC 60947-5-1
Storage Temperature-25-85 °C
Width22.5 mm

Specifications

[Us] Rated Supply Voltage24 V AC - 15...10 % || 24 V DC - 20...20 %
Safety Levelcan reach PL e/category 4 ISO 13849-1 || can reach SILCL 3 IEC 62061 || can reach SIL 3 IEC 61508
Range Of ProductHarmony Safety Automation
Product Or Component Typesafety module
Safety Module NameXPSUAF
Connections - Terminalsremovable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Safety Module Applicationmonitoring antivalent contacts || for emergency stop, guard and light curtain monitoring
Safety Reliability DataMTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 1.13E-09 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 1.13E-09 IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 1.13E-09 IEC 61508-1 || SFF > 99% IEC 61508-1 || type = B IEC 61508-1
Electrical Circuit TypeNC pair || PNP pair || antivalent pair || OSSD pair
Function Of Moduleemergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE) || proximity sensor monitoring

Complementary

Number Of Outputs3 on/off configurable pulsed output
Net Weight0.200 kg
Type Of Startautomatic/manual/monitored
Number Of Inputs2 safety input 24 V DC 5
Input Compatibilitynormally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
Power Consumption In Va5.0 VA 24 V AC 50/60 Hz
[Ie] Rated Operational Current5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact
Auxiliary Contact Composition3 NO
[Ui] Rated Insulation Voltage250 V 2)EN/IEC 60947-1
Power Consumption In W2.0 W 24 V DC
Maximum Line Resistance500 Ohm
Height100 mm
Local Signallingfor power ON LED (green) || for error LED (red) || for start LED (yellow) || for safety status LED (yellow) || for safety input S12 LED (yellow) || for safety input S22 LED (yellow)
Input Protection Typeinternal, electronic
Width22.5 mm
Depth120 mm
Synchronisation Time Between Inputs0.5 s || 2 s || 4 s
Maximum Response Time On Input Open20 ms
Mounting Support35 mm symmetrical DIN rail
Minimum Output Voltage15 V relay output
Minimum Output Current10 mA relay output
[Ith] Conventional Free Air Thermal Current8 A
Input/Output Typesemiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
Associated Fuse Rating10 A gG NO relay output circuit IEC 60947-1
[Uimp] Rated Impulse Withstand Voltage4 kV II EN/IEC 60947-1

Offer Sustainability

Rohs Exemption InformationYes
Circularity ProfileENVEOLI1811003EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Mercury FreeYes
Environmental DisclosureENVPEP1811003EN
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationX

Environment

Product CertificationsTÜV || cULus
Ip Degree Of ProtectionIP20 terminals)EN/IEC 60529 || IP40 housing)EN/IEC 60529 || IP54 mounting area)EN/IEC 60529
StandardsIEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard
Ambient Air Temperature For Storage-25-85 °C
Relative Humidity5-95 % non-condensing

Documentazione


Spesso acquistati assieme


Articoli correlati


Richiedi un preventivo