Redundancy module - QUINT-ORING/24DC/2X40/1X80 - 2902879
- Produttore:
- PHOENIX CONTACT
Active QUINT redundancy module for DIN rail mounting with ACB (Auto Current Balancing) Technology and monitoring functions, input: 24 V DC/2x 40 A, output: 24 V DC/1 x 80 A, including mounted UTA 107/30 universal DIN rail adapter
Features
Service life of the redundant solution is doubled, thanks to uniform distribution of the load
Save energy
Permanent monitoring of redundancy
Consistent redundancy up to the load
BV
cULus Listed
EAC
cULus Recognized
LR
RINA
NK
DNV GL
ABS
UL Listed
cUL Listed
UL Recognized
cUL Recognized
Specifications
Depth | 125 mm |
---|---|
Height | 130 mm |
Output Voltage | 0.2 V |
Strip Length | 10 mm |
Voltage | 10 V |
Width | 66 mm |
Ambient conditions | |
Ambient temperature (operation) | -25 °C - 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (start-up type tested) | -40 °C |
Ambient temperature (storage/transport) | -40 °C - 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Installation height | 2000 m |
Degree of protection | IP20 |
Conformance/approvals | |
UL approvals | UL/C-UL listed UL 508 |
UL approvals | UL/C-UL Recognized UL 60950-1 |
UL approvals | UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 25; |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Standards | |
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage | IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
Dimensions | |
Width | 66 mm |
Height | 130 mm |
Depth | 125 mm |
Width with alternative assembly | 122 mm |
Height with alternative assembly | 130 mm |
Depth with alternative assembly | 69 mm |
Installation distance right/left | 5 mm / 5 mm |
Installation distance top/bottom | 50 mm / 50 mm |
EMC data | |
Voltage | 10 V (Test Level 3) |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Electrostatic discharge | EN 61000-4-2 |
Contact discharge | 8 kV (Test Level 4) |
Discharge in air | 15 kV (Test Level 4) |
Electromagnetic HF field | EN 61000-4-3 |
Frequency range | 80 MHz - 1 GHz |
Test field strength | 20 V/m (Test Level 3) |
Frequency range | 1 GHz - 2 GHz |
Frequency range | 2 GHz - 3 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst) | EN 61000-4-4 |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 2 kV (Test Level 4 - asymmetrical) |
Comments | Criterion B |
Surge voltage load (surge) | EN 61000-4-5 |
Input | 1 kV (Test Level 2 - symmetrical) |
Output | 1 kV (Test Level 2 - symmetrical) |
Signal | 1 kV (Test Level 2 - asymmetrical) |
I/O/S | asymmetrical |
Frequency range | 0.15 MHz - 80 MHz |
Output data | |
Nominal output voltage | 0.2 V (< DC input) |
Nominal output voltage | 24 V DC |
Nominal output current (IN) | 80 A (Increasing power) |
Nominal output current (IN) | 40 A (Redundancy) |
Derating | 60 °C - 70 °C (2.5%/K) |
Connection in series | No |
Protection against overvoltage at the output (OVP) | ≤ 32 V DC |
Power loss nominal load max. | 16 W (IOUT = 80 A) |
Connection data, input | |
Connection method | Screw connection |
Conductor cross section solid min. | 0.5 mm² |
Conductor cross section solid max. | 16 mm² |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 16 mm² |
Conductor cross section AWG min. | 6 |
Stripping length | 10 mm |
Screw thread | M4 |
Connection data, output | |
Connection method | Screw connection |
Conductor cross section solid min. | 0.5 mm² |
Conductor cross section solid max. | 35 mm² |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 35 mm² |
Conductor cross section AWG min. | 2 |
Stripping length | 18 mm |
Screw thread | M5 |
Input data | |
Nominal input voltage range | 24 V DC |
Input voltage range | 18 V DC - 28 V DC (SELV) |
Nominal input current | 2x 40 A (-25 °C - 60 °C) |
Nominal input current | 1x 80 A (-25 °C - 60 °C) |
Maximum input current | 2x 45 A (-25°C - 40°C) |
Maximum input current | 1x 90 A (-25°C - 40°C) |
Maximum input current | 215 A (12 ms, SFB Technology) |
Connection data for signaling | |
Connection method | Screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 16 |
Conductor cross section AWG max. | 10 |
Stripping length | 10 mm |
Screw thread | M3 |