Redundancy module - QUINT-ORING/24DC/2X40/1X80 - 2902879

Produttore:
PHOENIX CONTACT
Phoenix contact

0b242fcf82183b13d8ad9e9f498387d81cd42f76 medium
Prezzo (IVA esclusa)
€ 592.92
Codice Nuova Elva
2902879
Codice produttore
2902879
Disponibilità
Invia RdO

Active QUINT redundancy module for DIN rail mounting with ACB (Auto Current Balancing) Technology and monitoring functions, input: 24 V DC/2x 40 A, output: 24 V DC/1 x 80 A, including mounted UTA 107/30 universal DIN rail adapter

Features

  • Service life of the redundant solution is doubled, thanks to uniform distribution of the load

  • Save energy

  • Permanent monitoring of redundancy

  • Consistent redundancy up to the load

  • BV

  • cULus Listed

  • EAC

  • cULus Recognized

  • LR

  • RINA

  • NK

  • DNV GL

  • ABS

  • UL Listed

  • cUL Listed

  • UL Recognized

  • cUL Recognized

Specifications

Depth125 mm
Height130 mm
Output Voltage0.2 V
Strip Length10 mm
Voltage10 V
Width66 mm

Ambient conditions

Ambient temperature (operation)-25 °C - 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested)-40 °C
Ambient temperature (storage/transport)-40 °C - 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height2000 m
Degree of protectionIP20

Conformance/approvals

UL approvalsUL/C-UL listed UL 508
UL approvalsUL/C-UL Recognized UL 60950-1
UL approvalsUL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 25;
China RoHSFor details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Standards

Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)

Dimensions

Width66 mm
Height130 mm
Depth125 mm
Width with alternative assembly122 mm
Height with alternative assembly130 mm
Depth with alternative assembly69 mm
Installation distance right/left5 mm / 5 mm
Installation distance top/bottom50 mm / 50 mm

EMC data

Voltage10 V (Test Level 3)
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Electrostatic dischargeEN 61000-4-2
Contact discharge8 kV (Test Level 4)
Discharge in air15 kV (Test Level 4)
Electromagnetic HF fieldEN 61000-4-3
Frequency range80 MHz - 1 GHz
Test field strength20 V/m (Test Level 3)
Frequency range1 GHz - 2 GHz
Frequency range2 GHz - 3 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A
Fast transients (burst)EN 61000-4-4
Input2 kV (Test Level 3 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal2 kV (Test Level 4 - asymmetrical)
CommentsCriterion B
Surge voltage load (surge)EN 61000-4-5
Input1 kV (Test Level 2 - symmetrical)
Output1 kV (Test Level 2 - symmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
I/O/Sasymmetrical
Frequency range0.15 MHz - 80 MHz

Output data

Nominal output voltage0.2 V (< DC input)
Nominal output voltage24 V DC
Nominal output current (IN)80 A (Increasing power)
Nominal output current (IN)40 A (Redundancy)
Derating60 °C - 70 °C (2.5%/K)
Connection in seriesNo
Protection against overvoltage at the output (OVP)≤ 32 V DC
Power loss nominal load max.16 W (IOUT = 80 A)

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.16 mm²
Conductor cross section AWG min.6
Stripping length10 mm
Screw threadM4

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.35 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.35 mm²
Conductor cross section AWG min.2
Stripping length18 mm
Screw threadM5

Input data

Nominal input voltage range24 V DC
Input voltage range18 V DC - 28 V DC (SELV)
Nominal input current2x 40 A (-25 °C - 60 °C)
Nominal input current1x 80 A (-25 °C - 60 °C)
Maximum input current2x 45 A (-25°C - 40°C)
Maximum input current1x 90 A (-25°C - 40°C)
Maximum input current215 A (12 ms, SFB Technology)

Connection data for signaling

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.16
Conductor cross section AWG max.10
Stripping length10 mm
Screw threadM3